4.5 Article

High-frequency Ultrasound Assessment of Systemic Sclerosis Skin Involvement: Intraobserver Repeatability and Relationship With Clinician Assessment and Dermal Collagen Content

期刊

JOURNAL OF RHEUMATOLOGY
卷 48, 期 6, 页码 867-876

出版社

J RHEUMATOL PUBL CO
DOI: 10.3899/jrheum.200234

关键词

collagen; skin; systemic sclerosis; ultrasonography

资金

  1. Scleroderma Raynaud's UK

向作者/读者索取更多资源

Using high-frequency ultrasound for objective assessment of cutaneous fibrosis in systemic sclerosis shows strong correlations with local mRSS and dermal collagen. Detection of subclinical abnormalities and high intraobserver repeatability support further investigation of HFUS as an alternative to mRSS in clinical trial settings.
Objective. The modified Rodnan skin score (mRSS) remains the preferred method for skin assessment in systemic sclerosis (SSc). There are concerns regarding high interobserver variability of mRSS and negative clinical trials utilizing mRSS as the primary endpoint. High-frequency ultrasound (HFUS) allows objective assessment of cutaneous fibrosis in SSc. We investigated the relationship between HFUS with both mRSS and dermal collagen. Methods. Skin thickness (ST), echogenicity, and novel shear wave elastography (SWE) were assessed in 53 patients with SSc and 15 healthy controls (HCs) at the finger, hand, forearm, and abdomen. The relationship between HFUS parameters with mRSS (n = 53) and dermal collagen (10 patients with SSc and 10 HCs) was investigated. Intraobserver repeatability of HFUS was calculated using intraclass correlation coefficients (ICCs). Results. HFUS assessment of ST (hand/forearm) and SWE (finger/hand) correlated with local mRSS at some sites. Subdinical abnormalities in ST, echogenicity, and SWE were present in clinically uninvolved SSc skin. Additionally, changes in echogenicity and SWE were sometimes apparent despite objectively normal ST on HFUS. ST, SWE, and local mRSS correlated strongly with collagen quantification (r = 0.697, 0.709, 0.649, respectively). Intraobserver repeatability was high for all HFUS parameters (ICCs for ST = 0.946-0.978; echogenicity = 0.648-0.865; and SWE = 0.953-0.973). Conclusion. Our data demonstrate excellent reproducibility and reassuring convergent validity with dermal collagen content. Detection of subclinical abnormalities is an additional benefit of HFUS. The observed correlations with collagen quantification support further investigation of HFUS as an alternative to mRSS in clinical trial settings.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据