4.6 Article

Validation of the Alpha Defensin Lateral Flow Test for Periprosthetic Joint Infection

期刊

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.2106/JBJS.20.00749

关键词

-

向作者/读者索取更多资源

The study demonstrated the solid diagnostic performance of the alpha defensin test in diagnosing PJI and resulted in FDA authorization for the lateral-flow test as an aid in the clinical diagnosis of PJI.
Background: The synovial fluid test for alpha defensin has been reported to have an excellent performance in diagnosing periprosthetic joint infection (PJI). The purpose of this study was to evaluate the performance of the lateral flow test for synovial fluid alpha defensin by using the methods of a formal diagnostic accuracy study and to compare its performance with that of the laboratory-based alpha defensin test for PJI. Methods: We conducted a diagnostic accuracy study of the index lateral flow immunoassay for synovial fluid alpha defensin relative to the reference 2013 Musculoskeletal Infection Society (MSIS) multicriteria definition of PJI. The study included a prospective multicenter cohort of outpatients with a failed hip or knee arthroplasty and a supplemental control cohort of fresh synovial fluid specimens submitted by physicians for diagnostic PJI testing. Results: Among 57 patients with PJI and 248 patients without PJI in the overall prospective patient cohort, the sensitivity and specificity of the alpha defensin lateral flow test were 89.5% (95% confidence interval [CI]: 78.5% to 96.0%) and 94.8% (95% CI: 91.2% to 97.2%), respectively. The sensitivity increased to 94.3% (95% CI: 84.3% to 98.8%) after exclusion of 17 patients with grossly bloody aspirates (>1 million red blood cells/mu L). Among the supplemental control cohort of fresh synovial fluid samples, including 65 samples from patients with PJI and 397 from patients without PJI, the sensitivity and specificity of the alpha defensin lateral flow test were 98.5% (95% CI: 91.7% to 100.0%) and 98.2% (95% CI: 96.4% to 99.3%), respectively. A comparison of the sensitivity and specificity of the alpha defensin lateral flow test with those of the alpha defensin enzyme-linked immunosorbent assay (ELISA) in the combined cohort did not demonstrate a significant difference in sensitivity (94.3% [95% CI: 88.5% to 97.7%] compared with 93.0% [95% CI: 87.1% to 96.7%]) or specificity (96.9% [95% CI: 95.3% to 98.1%] compared with 97.8% [95% CI: 96.4% to 98.8%]) (both p > 0.05). Conclusions: The results of this study demonstrate the solid diagnostic performance of the alpha defensin test and have resulted in the U.S. Food and Drug Administration (FDA) authorization of the lateral-flow test with an intended use as an aid in the clinical diagnosis of PJI.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据