EVALUATING RADIANT HEATER PERFORMANCE USING CHICK THERMAL PREFERENCE AND SPATIAL ANALYSIS

期刊

APPLIED ENGINEERING IN AGRICULTURE
卷 37, 期 3, 页码 447-454

出版社

AMER SOC AGRICULTURAL & BIOLOGICAL ENGINEERS
DOI: 10.13031/aea.14466

关键词

Broiler chicks; Brooding; Net usable area; Radiant heaters; Thermal preference

资金

  1. USDA Agricultural Research Service [58-6406-1-643]
  2. Mississippi Agriculture and Forestry Experiment Station of Mississippi State University
  3. Alabama Agricultural Experiment Station
  4. Hatch Program of the USDA National Institute of Food and Agriculture

向作者/读者索取更多资源

This study investigated the efficiency of radiant heaters from different manufacturers in providing a suitable warm environment for brooding chicks, finding that heaters with the same power output do not necessarily produce the same net usable area (NUA). Additionally, chicks were shown to decrease their preference for radiant flux levels during the first week of brooding, resulting in higher NUA at 8 days compared to 1 day.
Radiant heaters are the most common method of providing supplemental heat in broiler houses, but little is known about how efficiently they create a suitable thermal environment for brooding chicks. This study investigates the net usable area (NUA), or the total floor area within the range of radiant flux preferred by chicks, for six round radiant heaters with a nominally rated power output of 11.72 kW. NUA was calculated for all heaters at three manufacturer specified heights 1.52, 1.83, and 1.98 m and at a distance 0.3 m below manufacturer specified height (1.22 m). NUA ranged from 11.6 +/- 0.7 m(2) to 59.4 +/- 19.7 m(2) and increased with heater mounting elevation. Results indicate that radiant heaters from different manufacturers with the same power output do not produce the same NUA. NUA was also shown to be higher at 8 d than 1 d for all heaters and was attributed to the decrease in chick preference for level of radiant flux during the first week of brooding. NUA gross radiant coefficient (GRC), or the proportion of the heat energy in the fuel that reached the floor and was within the thermal comfort range of the chicks, did not exceed 0.37 for any heater and decreased with heater elevation. Operating a heater below the manufacturer specified mounting elevations led to reduced NUA and an overall less efficient use of fuel.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据