4.5 Article

Impact of Wildfire Smoke Events on Indoor Air Quality and Evaluation of a Low-cost Filtration Method

期刊

AEROSOL AND AIR QUALITY RESEARCH
卷 21, 期 7, 页码 -

出版社

TAIWAN ASSOC AEROSOL RES-TAAR
DOI: 10.4209/aaqr.210046

关键词

PM2.5; Indoor air pollution; Filtration; Biomass burning; Laser particle counter

向作者/读者索取更多资源

The study analyzed indoor and outdoor PM2.5 concentrations at 42 sites in the western US, finding lower penetration and suspended concentrations in residential buildings compared to commercial and school buildings. Interventions to improve indoor air quality had a significant impact on reducing PM2.5 infiltration in residential settings, with the low-cost MERV-13 fan filter unit proving effective in improving IAQ during wildfire smoke events.
Increased wildland fire activity is producing extreme fine particulate matter (PM2.5) concentrations impacting millions of people every year, especially in the western United States (US). Recommendations for limiting exposure to PM2.5 and associated adverse health outcomes focus on staying inside, closing windows and doors, and increasing filtration; however, relatively little is known about indoor air quality (IAQ) during major smoke events. Indoor and outdoor hourly PM2.5 (mu g m(-3)) measurements from the publicly available PurpleAir sensor (PAS) network were analyzed for 42 sites (26 residential, 6 school, 10 commercial) across the western US during a September 2020 period of heavy wildfire smoke influence. The fraction of ambient PM2.5 that penetrates indoors and remains airborne (F-in), as well as the ratio (I/O) and correlation coefficient (R-2) of indoor to outdoor PM2.5 concentrations, were lower in residential compared to commercial and school buildings. Interventions to improve IAQ were highly influential in PM2.5 infiltration in residential case studies, with multiple, continuously run filter units associated with lower F-in, I/O, and R-2. A low-cost PM2.5 filtration method consisting of a Minimum Efficiency Rating Value-13 (MERV-13) filter attached to a box fan is evaluated as an alternative for improving IAQ during wildland fire smoke events. The MERV-13 fan filter unit proved highly effective at reducing indoor PM2.5 and particles 0.3-1.0 mu m measured by PAS and a particle counter, respectively, when recirculating air in a single room. Low-cost filtration methods can have significant benefit for filtering submicron smoke particles and may reduce exposure to PM2.5 during wildfire smoke events.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据