4.6 Review

Diagnostic Performance of Prostate Imaging Reporting and Data System Version 2 for Detection of Prostate Cancer: A Systematic Review and Diagnostic Meta-analysis

期刊

EUROPEAN UROLOGY
卷 72, 期 2, 页码 177-188

出版社

ELSEVIER
DOI: 10.1016/j.eururo.2017.01.042

关键词

Prostate imaging reporting and data system version 2; Prostate cancer; Magnetic resonance imaging; Meta-analysis

向作者/读者索取更多资源

Context: In 2015, the updated Prostate Imaging Reporting and Data System version 2 (PI-RADSv2) for the detection of prostate cancer (PCa) was established. Since then, several studies assessing the value of PI-RADSv2 have been published. Objective: To review the diagnostic performance of PI-RADSv2 for the detection of PCa. Evidence acquisition: MEDLINE and EMBASE databases were searched up to December 7, 2016. We included diagnostic accuracy studies that used PI-RADSv2 for PCa detection, using prostatectomy or biopsy as the reference standard. The methodological quality was assessed by two independent reviewers using the Quality Assessment of Diagnostic Accuracy Studies-2 tool. Sensitivity and specificity of all studies were calculated. Results were pooled and plotted in a hierarchical summary receiver operating characteristic plot with further exploration using meta-regression and multiple subgroup analyses. Head-to-head comparison between PI-RADSv1 and PI-RADSv2 was performed for available studies. Evidence synthesis: Twenty-one studies (3857 patients) were included. The pooled sensitivity was 0.89 (95% confidence interval [CI] 0.86-0.92) with specificity of 0.73 (95% CI 0.60-0.83) for PCa detection. Proportion of patients with PCa, magnetic field strength, and reference standard were significant factors affecting heterogeneity (p < 0.01). Multiple subgroup analyses showed consistent results. In six studies performing head-to-head comparison, PI-RADSv2 demonstrated higher pooled sensitivity of 0.95 (95% CI 0.85-0.98) compared with 0.88 (95% CI 0.80-0.93) for PI-RADSv1 (p = 0.04). However, the pooled specificity was not significantly different (0.73 [95% CI 0.47-0.89] vs 0.75 [95% CI 0.36-0.94], respectively; p = 0.90). Conclusions: PI-RADSv2 shows good performance for the detection of PCa. PI-RADSv2 has higher pooled sensitivity than PI-RADSv1 without significantly different specificity. Patient summary: We reviewed all previous studies using Prostate Imaging Reporting and Data System version 2 (PI-RADSv2) for prostate cancer detection. We found that the updated PI-RADSv2 shows significant improvement compared with the original PIRADSv1. (C) 2017 European Association of Urology. Published by Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据