This paper presents a novel approach for diagnosing inter-turn faults in line-start permanent magnet synchronous motors operating under nonstationary conditions. The proposed method has been shown to be successful and effective in detecting faults in LSPMSMs.
Inter-turn faults are one of the most important issues in line-start permanent magnet synchronous motors (LSPMSMs). To date, steady-state operating conditions of LSPMSMs have been analyzed in studies focusing on diagnosing this fault. However, no studies have been conducted for nonstationary operating conditions, such as variable speed or variable load conditions, which are common in the industry. This paper presents a novel approach for fault harmonic component (FHC) tracking based on transient-MCSA to diagnose inter-turn faults in an LSPMSM operating under nonstationary conditions. First, the inter-turn failure model of LSPMS was analyzed to show the fault effect on motor current, and the most dominant inter-turn FHC in the order and frequency domains were determined. Then, using Gabor-OT, inter-turn FHC signals were extracted from motor current signals in the frequency domain and reconstructed in the time domain. Intrinsic mode functions (IMFs) were calculated by decomposing the reconstructed FHC signals (RFHCSs) via ensemble empirical mode decomposition. Using the energies of RFHCSs, calculated based on Gabor coefficients, and the Kullback-Leibler divergences of the selected IMFs, diagnosis of the inter-turn faults and detection of the severity of the faults was performed. The results are in agreement with the results in the literature, thus showing that the proposed method is a successful and useful means for detecting inter-turn faults in LSPMSMs.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据