4.5 Article

Highly sensitive detection of antibody nonspecific interactions using flow cytometry

期刊

MABS
卷 13, 期 1, 页码 -

出版社

TAYLOR & FRANCIS INC
DOI: 10.1080/19420862.2021.1951426

关键词

Developability; nonspecific; non-specific; polyreactivity; off-target binding; specificity; affinity; bispecific; multispecific; mAb; IgG; Fc; Fab

资金

  1. Biomolecular Interaction Technology Center at the University of Delaware
  2. National Institutes of Health [T32GM008353, R35GM136300]
  3. Albert M. Mattocks Chair

向作者/读者索取更多资源

The PolySpecificity Particle (PSP) assay is a sensitive flow cytometry method for evaluating antibody nonspecific interactions, overcoming previous limitations and allowing for evaluation of diverse types of antibodies. This assay is more sensitive than standard assays like ELISAs, and has the potential to accelerate the development of safe and effective antibody therapeutics.
The rapidly evolving nature of antibody drug development has resulted in technologies that generate vast numbers (hundreds to thousands) of lead antibody candidates during early discovery. These candidates must be rapidly pared down to identify the most drug-like candidates for in-depth analysis of their safety and efficacy, which can only be performed on a limited number of antibodies due to time and resource requirements. One key biophysical property of successful antibody therapeutics is high specificity, defined as low levels of nonspecific binding or polyspecificity. Although there has been some progress in developing assays for detecting antibody polyspecificity, most of these assays are limited by poor sensitivity or assay formats that require proprietary antibody surface display methods, and some of these assays use complex and poorly defined polyspecificity reagents. Here we report the PolySpecificity Particle (PSP) assay, a sensitive flow cytometry assay for evaluating antibody nonspecific interactions that overcomes previous limitations and can be used for evaluating diverse types of IgGs, multispecific antibodies and Fc-fusion proteins. Our approach uses micron-sized magnetic beads coated with Protein A to capture antibodies at extremely dilute concentrations (<0.02 mg/mL). Flow cytometry analysis of polyspecificity reagent binding to these conjugates results in sensitive detection of differences in nonspecific interactions for clinical-stage antibodies. Our PSP assay strongly discriminates between antibodies with different levels of polyspecificity using previously reported polyspecificity reagents that are either well-defined proteins or highly complex protein mixtures. Moreover, we also find that a unique reagent, namely ovalbumin, results in the best assay sensitivity and specificity. Importantly, our assay is much more sensitive than standard assays such as ELISAs. We expect that our simple, sensitive, and high-throughput PSP assay will accelerate the development of safe and effective antibody therapeutics.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据