A New Method for Aortic Valve Planimetry with High-Resolution 3-Dimensional MRI and Its Comparison with Conventional Cine MRI and Echocardiography for Assessing the Severity of Aortic Valvular Stenosis

期刊

KOREAN JOURNAL OF RADIOLOGY
卷 22, 期 8, 页码 1266-1278

出版社

KOREAN RADIOLOGICAL SOC
DOI: 10.3348/kjr.2020.1218

关键词

Aortic valve; Aortic stenosis; Planimetry; Cardiac magnetic resonance imaging; Echocardiography

向作者/读者索取更多资源

This study compared the aortic valve area calculated using fast high-resolution three-dimensional magnetic resonance imaging with that of conventional two-dimensional imaging. The results showed that the high-resolution 3D MR imaging technique had low observer variability and highly correlated with transthoracic echocardiography measurements.
Objective: We aimed to compare the aortic valve area (AVA) calculated using fast high-resolution three-dimensional (3D) magnetic resonance (MR) image acquisition with that of the conventional two-dimensional (2D) cine MR technique. Materials and Methods: We included 139 consecutive patients (mean age +/- standard deviation [SD], 68.5 +/- 9.4 years) with aortic valvular stenosis (AS) and 21 asymptomatic controls (52.3 +/- 14.2 years). High-resolution T2-prepared 3D steady-state free precession (SSFP) images (2.0 mm slice thickness, 10 contiguous slices) for 3D planimetry (3DP) were acquired with a single breath hold during mid-systole. 2D SSFP cine MR images (6.0 mm slice thickness) for 2D planimetry (2DP) were also obtained at three aortic valve levels. The calculations for the effective AVA based on the MR images were compared with the transthoracic echocardiographic (TTE) measurements using the continuity equation. Results: The mean AVA +/- SD derived by 3DP, 2DP, and TTE in the AS group were 0.81 +/- 0.26 cm(2), 0.82 +/- 0.34 cm(2), and 0.80 +/- 0.26 cm(2), respectively (p = 0.366). The intra-observer agreement was higher for 3DP than 2DP in one observer: intraclass correlation coefficient (ICC) of 0.95 (95% confidence interval [CI], 0.94-0.97) and 0.87 (95% CI, 0.82-0.91), respectively, for observer 1 and 0.97 (95% CI, 0.96-0.98) and 0.98 (95% CI, 0.97-0.99), respectively, for observer 2. Inter-observer agreement was similar between 3DP and 2DP, with the ICC of 0.92 (95% CI, 0.89-0.94) and 0.91 (95% CI, 0.88-0.93), respectively. 3DP-derived AVA showed a slightly higher agreement with AVA measured by TTE than the 2DP-derived AVA, with the ICC of 0.87 (95% CI, 0.82-0.91) vs. 0.85 (95% CI, 0.79-0.89). Conclusion: High-resolution 3D MR image acquisition, with single-breath-hold SSFP sequences, gave AVA measurement with low observer variability that correlated highly with those obtained by TTE.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据