4.6 Article

Noncontact Respiratory Measurement for Multiple People at Arbitrary Locations Using Array Radar and Respiratory-Space Clustering

期刊

IEEE ACCESS
卷 9, 期 -, 页码 106895-106906

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/ACCESS.2021.3099821

关键词

Radar; Radar measurements; Radar imaging; Chirp; Millimeter wave measurements; Estimation; Biomedical measurement; Antenna arrays; biomedical engineering; clustering methods; Doppler radar; MIMO radar; radar measurements; radar imaging; radar signal processing

资金

  1. JSPS KAKENHI [19H02155]
  2. JST PRESTO [JPMJPR1873]
  3. JST COI [JPMJCE1307]
  4. Grants-in-Aid for Scientific Research [19H02155] Funding Source: KAKEN

向作者/读者索取更多资源

A noncontact measurement system using millimeter-wave array radar was developed to monitor the respiration of multiple people, proposing a respiratory-space clustering method to accurately resolve echoes from human bodies. The method showed improved accuracy in estimating the number of people and respiratory intervals, demonstrating its effectiveness in measuring the respiration of multiple individuals.
We developed a noncontact measurement system for monitoring the respiration of multiple people using millimeter-wave array radar. To separate the radar echoes of multiple people, conventional techniques cluster the radar echoes in the time, frequency, or spatial domain. Focusing on the measurement of the respiratory signals of multiple people, we propose a method called respiratory-space clustering, in which individual differences in the respiratory rate are effectively exploited to accurately resolve the echoes from human bodies. The proposed respiratory-space clustering can separate echoes, even when people are located close to each other. In addition, the proposed method can be applied when the number of targets is unknown and can accurately estimate the number and positions of people. We perform multiple experiments involving five or seven participants to verify the performance of the proposed method, and quantitatively evaluate the estimation accuracy for the number of people and the respiratory intervals. The experimental results show that the average root-mean-square error in estimating the respiratory interval is 196 ms using the proposed method. The use of the proposed method, rather the conventional method, improves the accuracy of the estimation of the number of people by 85.0%, which indicates the effectiveness of the proposed method for the measurement of the respiration of multiple people.