4.5 Article

Emphysema quantification and lung volumetry in chest X-rayequivalent ultralow dose CT - Intra-individual comparison with standard dose CT

期刊

EUROPEAN JOURNAL OF RADIOLOGY
卷 91, 期 -, 页码 1-9

出版社

ELSEVIER IRELAND LTD
DOI: 10.1016/j.ejrad.2017.03.003

关键词

Computed tomography; Ultralow dose; Emphysema; Radiation dose; Iterative reconstructiona

向作者/读者索取更多资源

Objectives: To determine whether ultralow dose chest CT with tin filtration can be used for emphy semaquantification and lung volumetry and to assess differences in emphysema measurements and lung volume between standard dose and ultralow dose CT scans using advanced modeled iterative reconstruction(ADMIRE). Methods: 84 consecutive patients from a prospective, IRB-approved single-center study were included and underwent clinically indicated standard dose chest CT (1.7 perpendicular to 0.6 mSv) and additional single-energy ultralow dose CT (0.14 +/- 0.01 mSv) at 100 kV and fixed tube current at 70 mAs with tin filtration in the same session. Forty of the 84 patients (48%) had no emphysema, 44 (52%) had emphysema. One radiologist performed fully automated software-based pulmonary emphysema quantification and lung volumetry of standard and ultralow dose CT with different levels of ADMIRE. Friedman test and Wilcoxon rank sum test were used for multiple comparison of emphysema and lung volume. Lung volumes were compared using the concordance correlation coefficient. Results: The median low-attenuation areas (LAA) using filtered back projection (FBP) in standard dose was 4.4% and decreased to 2.6%, 2.1% and 1.8% using ADMIRE 3, 4, and 5, respectively. The median values of LAA in ultralow dose CT were 5.7%, 4.1% and 2.4% for ADMIRE 3, 4, and 5, respectively. There was no statistically significant difference between LAA in standard dose CT using FBP and ultralow dose using ADMIRE 4 (p = 0.358) as well as in standard dose CT using ADMIRE 3 and ultralow dose using ADMIRE5 (p = 0.966). In comparison with standard dose FBP the concordance correlation coefficients of lung volumetry were 1.000, 0.999, and 0.999 for ADMIRE 3, 4, and 5 in standard dose, and 0.972 for ADMIRE3, 4 and 5 in ultralow dose CT. Conclusions: Ultralow dose CT at chest X-ray equivalent dose levels allows for lung volumetry as well as detection and quantification of emphysema. However, longitudinal emphysema analyses should be performed with the same scan protocol and reconstruction algorithms for reproducibility. (C) 2017 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据