3.8 Article

A Simple Device and Biplanar Technique to Improve Precision When Templating for Total Joint Arthroplasty

期刊

TECHNIQUES IN ORTHOPAEDICS
卷 36, 期 3, 页码 295-297

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/BTO.0000000000000447

关键词

templating; total hip replacement; planning; scaling; calibration

向作者/读者索取更多资源

Accurate templating for arthroplasty procedures relies on reliably estimating image magnification. The authors' simple device using staggered marker balls in orthogonal imaging proved to be more precise compared to assuming a constant 20% magnification for all x-rays, with the novel technique having no outliers exceeding 4% error.
Accurate templating for arthroplasty procedures depends on reliably estimating image magnification. The authors designed a simple device and technique to accomplish this. It is a wedge with four 25-mm balls staggered at different heights, each representing a potential marker. The proper ball to use as the scaling marker is identified on an orthogonal view on the basis of its relationship with the anatomic feature of interest. Reviewing x-rays with known acetabular component diameters, the authors found that the staggered balls technique had a scaling error of 1.48 +/- 0.89%. Assuming a constant 20% magnification for all x-rays resulted in an error of 1.65 +/- 1.59%. Although similarly accurate, the difference in precision was found to be significant (P=0.012). The constant magnification method resulted in 2 outliers with >4% error, whereas there were no outliers with the novel technique. Staggered marker balls combined with orthogonal imaging is accurate and improves the precision of estimating radiograph magnification.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

3.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据