4.6 Article

Comparing the diagnostic accuracy of point-of-care lateral flow antigen testing for SARS-CoV-2 with RT-PCR in primary care (REAP-2)

期刊

ECLINICALMEDICINE
卷 38, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.eclinm.2021.101011

关键词

Lateral flow antigen testing; Point-of-care testing; SARS-CoV-2; COVID-19, Primary care; Sensitivity; Specificity

资金

  1. European Union's Horizon 2020 Research and Innovation Programe [101016233]

向作者/读者索取更多资源

The study demonstrates that LFT is a viable alternative to RT-PCR testing in primary care, showing high sensitivity and specificity. It also suggests that the reliability of LFT may be affected by the duration of symptoms and Ct values.
Background: Testing for COVID-19 with quantitative reverse transcriptase-polymerase chain reaction (RT-PCR) may result in delayed detection of disease. Antigen detection via lateral flow testing (LFT) is faster and amenable to population-wide testing strategies. Our study assesses the diagnostic accuracy of LFT compared to RT-PCR on the same primarycare patients in Austria. Methods: Patients with mild to moderate flu-like symptoms attending a general practice network in an Austrian district (October 22 to November 30, 2020) received clinical assessment including LFT. All suspected COVID-19 cases obtained additional RT-PCR and were divided into two groups: Group 1 (true reactive): suspected cases with reactive LFT and positive RT-PCR; and Group 2 (false non-reactive): suspected cases with a non-reactive LFT but positive RT-PCR. Findings: Of the 2,562 symptomatic patients, 1,037 were suspected of COVID-19 and 826 (79.7%) patients tested RT-PCR positive. Among patients with positive RT-PCR, 788/826 tested LFT reactive (Group 1) and 38 (4.6%) non-reactive (Group 2). Overall sensitivity was 95.4% (95%CI: [94%,96.8%]), specificity 89.1% (95%CI: [86.3%, 91.9%]), positive predictive value 97.3% (95%Cl: [95.9%, 98.7%]) and negative predictive value 82.5% (95%CI: [79.8%, 85.2%]). Reactive LFT and positive RT-PCR were positively correlated (r = 0.968,95CI= [0.952,0.985] and kappa = 0.823, 95%CI=[0.773,0.866]). Reactive LFT was negatively correlated with Ct-value (r = -0.2999,p < 0.001) and pre-test symptom duration (r = -0.1299,p = 0.0043) while Ct-value was positively correlated with pre-test symptom duration (r = 0.3733),p < 0.001). Interpretation: We show that LFT is an accurate alternative to RT-PCR testing in primary care. We note the importance of administering LFT properly, here combined with clinical assessment in symptomatic patients. (C) 2021 The Authors. Published by Elsevier Ltd.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据