4.2 Article

EVALUATION OF SOIL MOISTURE SENSING TECHNOLOGIES IN SILT LOAM AND LOAMY SAND SOILS: ASSESSMENT OF PERFORMANCE, TEMPERATURE SENSITIVITY, AND SITE- AND SENSOR-SPECIFIC CALIBRATION FUNCTIONS

期刊

TRANSACTIONS OF THE ASABE
卷 64, 期 4, 页码 1123-1139

出版社

AMER SOC AGRICULTURAL & BIOLOGICAL ENGINEERS
DOI: 10.13031/trans.14112

关键词

Capacitance; Irrigation; Sensors; Site-specific calibration; Soil moisture; TDR; Time-domain reflectometry

资金

  1. National Science Foundation (NSF) [CNS-1619285]
  2. USDA National Institute of Food and Agriculture (Hatch Project) [NEB-21-155]

向作者/读者索取更多资源

Different types of soil moisture sensors were investigated in various soil types and installation orientations, with performance mainly affected by sensor type and soil type. Precision and accuracy were key factors in sensor selection, with site-specific calibration significantly improving sensor performance in certain soil types.
Reliable soil moisture information is vital for optimal irrigation management, farm-level agronomic decision-making, hydrologic studies, and cropping systems modeling. A wide range of soil moisture sensing technologies is commercially available, but their performance must be evaluated for diverse conditions of use. In this research, we investigated nine soil moisture sensors based on time-domain reflectometry, capacitance, and electrical resistance principles in production field conditions with two installation orientations, i.e., vertical (V) and horizontal (H), in two soils (silt loam and loamy sand) and two growing seasons (2017 and 2018). Performance parameters deduced from the 2017 datasets revealed that sensor type and soil type significantly affected the soil moisture sensor performance under factory calibration (F.C.); however, sensor installation orientation did not. Thus, the sensors were only evaluated based on their performance in horizontal orientation in both soils. Precision and accuracy were considered targets to assist in appropriate sensor selection. To improve sensor accuracy, site-specific calibration (S.S.C.) functions were developed and validated using independent datasets from 2018. Considering mean bias error (MBE), all sensors overestimated volumetric soil water content (theta(v)) in both soils, with the exception of TEROS 21 (MPS-6) in silt loam and JD probe in loamy sand. On average, sensor performance was 67% better in loamy sand than in silt loam. Overall, the sensors showed higher precision in silt loam (R-2 = 0.53 to 0.93) than in loamy sand (R-2 = 0.25 to 0.82). Substantial post-S.S.C. improvement (32% to 89%) was observed in all sensors' performance relative to F.C. in silt loam. In loamy sand, while most sensors performed reasonably well with F.C., considerable improvements (28% to 85%) were observed with S.S.C. Significant differences (p < 0.05) were observed in sensors' sensitivity to soil temperature (T-soil), which ranged from 14 degrees C to 23 degrees C in silt loam and from 14 degrees C to 25 degrees C loamy sand during the experiments. The CS655, 10HS, 5TE, and TEROS 21 (MPS-6) sensors showed significant (p < 0.05) sensitivity to T-soil fluctuations, with T-soil explaining a maximum of 17% of the variance observed in sensor performance. No statistically significant (p > 0.05) sensitivity was detected for any of the sensors in loamy sand. TEROS 21 (MPS-6) had the highest sensitivity to T-soil with a slope of -4.25. In contrast, while statistically significant (p < 0.05), 5TE was the least sensitive to T-soil variability with a slope of 1.81. The information, data, and analyses presented here can be instrumental for informed sensor selection and use in decision-making in production fields with similar soil textures and soil water regimes.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.2
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据