The study utilizes AgI-KI aerosol catalysts to control and eliminate the formation of glaze icing on overhead transmission lines, with results showing a higher nucleation rate and improved deicing performance. These aerosols may be a better choice for deicing technology.
The glaze icing of overhead transmission lines seriously influences the security operation of the power grid, resulting in huge economic loss. Here, by employing AgI-KI aerosol catalysts with good combustion performance, we found that the formation of glaze icing could be controlled and eliminated before it causes damage to transmission lines, as revealed by a 0.5 m(3) low temperature cabinet, a 1 m(3) isothermal cloud chamber and a 60 m(3) environment climate chamber, respectively. The higher nucleation rate (similar to 10(15)) of AgI-KI aerosols than the blank (similar to 10(7)) was found to be beneficial for deicing performance. Our results suggest that such aerosols could be a better choice for deicing technology.