4.6 Article

Evaluation of table-top lasers for routine infrared ion spectroscopy in the analytical laboratory

期刊

ANALYST
卷 146, 期 23, 页码 7218-7229

出版社

ROYAL SOC CHEMISTRY
DOI: 10.1039/d1an01406d

关键词

-

资金

  1. Natural Sciences [VICI 724.011.002, TTW 15769, TKI-LIFT 731.017.419, Rekentijd 2019.062]
  2. NWO

向作者/读者索取更多资源

Infrared ion spectroscopy is recognized as a method to identify analytes detected by mass spectrometry in various chemical areas, with integration into analytical laboratories being considered. To overcome collisional deactivation at high pressures, high instantaneous power infrared lasers are needed, with most studies currently being performed at infrared free electron laser facilities. The proliferation of this technique in routine analytical laboratories requires table-top infrared lasers, such as optical parametric oscillators (OPOs), which offer high intensities and good spectral tuning ranges.
Infrared ion spectroscopy is increasingly recognized as a method to identify mass spectrometry-detected analytes in many (bio)chemical areas and its integration in analytical laboratories is now on the horizon. Commercially available quadrupole ion trap mass spectrometers are attractive ion spectroscopy platforms but operate at relatively high pressures. This promotes collisional deactivation which directly interferes with the multiple-photon excitation process required for ion spectroscopy. To overcome this, infrared lasers having a high instantaneous power are required and therefore a majority of analytical studies have been performed at infrared free electron laser facilities. Proliferation of the technique to routine use in analytical laboratories requires table-top infrared lasers and optical parametric oscillators (OPOs) are the most suitable candidates, offering both relatively high intensities and reasonable spectral tuning ranges. Here, we explore the potential of a range of commercially available high-power OPOs for ion spectroscopy, comparing systems with repetition rates of 10 Hz, 20 kHz, 80 MHz and a continuous-wave (cw) system. We compare the performance for various molecular ions and show that the kHz and MHz repetition-rate systems outperform cw and 10 Hz systems in photodissociation efficiency and offer several advantages in terms of cost-effectiveness and practical implementation in an analytical laboratory not specialized in laser spectroscopy.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据