4.5 Article

Atri-U: assisted image analysis in routine cardiovascular magnetic resonance volumetry of the left atrium

期刊

出版社

BMC
DOI: 10.1186/s12968-021-00791-8

关键词

Magnetic resonance imaging; Heart atria; Artificial intelligence; Workflow; Atrial fibrillation; Biplane area-length method

向作者/读者索取更多资源

The study achieved a substantial reduction in time required to read a cardiovascular magnetic resonance (CMR) study for estimating left atrial volume by combining automated LA volumetry with human interaction in image analysis. The assistance of Atri-U led to a significant reduction in reading time in a clinical setting and provided measurement results close to those of experts.
Background Artificial intelligence can assist in cardiac image interpretation. Here, we achieved a substantial reduction in time required to read a cardiovascular magnetic resonance (CMR) study to estimate left atrial volume without compromising accuracy or reliability. Rather than deploying a fully automatic black-box, we propose to incorporate the automated LA volumetry into a human-centric interactive image-analysis process. Methods and results Atri-U, an automated data analysis pipeline for long-axis cardiac cine images, computes the atrial volume by: (i) detecting the end-systolic frame, (ii) outlining the endocardial borders of the LA, (iii) localizing the mitral annular hinge points and constructing the longitudinal atrial diameters, equivalent to the usual workup done by clinicians. In every step human interaction is possible, such that the results provided by the algorithm can be accepted, corrected, or re-done from scratch. Atri-U was trained and evaluated retrospectively on a sample of 300 patients and then applied to a consecutive clinical sample of 150 patients with various heart conditions. The agreement of the indexed LA volume between Atri-U and two experts was similar to the inter-rater agreement between clinicians (average overestimation of 0.8 mL/m(2) with upper and lower limits of agreement of - 7.5 and 5.8 mL/m(2), respectively). An expert cardiologist blinded to the origin of the annotations rated the outputs produced by Atri-U as acceptable in 97% of cases for step (i), 94% for step (ii) and 95% for step (iii), which was slightly lower than the acceptance rate of the outputs produced by a human expert radiologist in the same cases (92%, 100% and 100%, respectively). The assistance of Atri-U lead to an expected reduction in reading time of 66%-from 105 to 34 s, in our in-house clinical setting. Conclusions Our proposal enables automated calculation of the maximum LA volume approaching human accuracy and precision. The optional user interaction is possible at each processing step. As such, the assisted process sped up the routine CMR workflow by providing accurate, precise, and validated measurement results.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据