3.8 Article

A LC-MS/MS method with electrospray ionization and atmospheric pressure chemical ionization source for analysis of pesticides in hemp

期刊

JOURNAL OF CANNABIS RESEARCH
卷 3, 期 1, 页码 -

出版社

BMC
DOI: 10.1186/s42238-021-00106-9

关键词

Hemp; Liquid chromatography-mass spectroscopy; Pesticides; Electrospray ion source; Atmospheric pressure chemical ionization source

向作者/读者索取更多资源

A streamlined LC-MS/MS method with dual ESI and APCI sources was developed for the analysis of 66 pesticides in hemp, with all pesticides showing acceptable recovery rates in the hemp matrix ranging from 80-120% with RSD less than 20%.
Background Pesticide testing for hemp has traditionally focused on techniques like QuEChERS with dSPE and SPE which demand time-consuming sample preparation, typically resulting in poor recovery rates for some pesticides, and requires the use of both LC-MS/MS and GC-MS/MS based instruments to cover the analysis for all regulated pesticides. In this study, we describe a streamlined approach for working with LC-MS/MS featuring a dual electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) sources using solvent extraction for faster and easier sample preparation and with 80-120% recovery for the analysis of all of 66 pesticides (regulated by California state in cannabis) with low detection limits in hemp. Methods A simple solvent extraction with acetonitrile was used to extract pesticides from hemp. A LC-MS/MS system with dual ESI and APCI source was used to determine sensitivity for the analysis of 66 pesticides in hemp matrix, 62 pesticides were analyzed using an 18-min LC-MS/MS method with an ESI source and the other 4 pesticides were measured using a 6-min LC-MS/MS method with an APCI source. Results The limit of quantitation (LOQ) of all 66 pesticides in hemp was in the range of 0.0025-0.1 mu g/g which was well below the California state action limits of these analytes in cannabis products. A simple, fast, and cost-effective solvent extraction method was used for sample preparation to get good recovery in the range of 80-120% with RSD less than 20%. The unique ionization mechanism of chlorinated pesticides such as pentachloronitrobenzene using the LC-MS/MS system with an APCI source was elucidated. The proficiency test report generated with the LC-MS/MS method showed acceptable results for all of 66 pesticides in hemp with all of th z scores less than 2 with no false positives and negatives. The stability data collected over 5 days showed RSD less than 20% for 66 pesticides in hemp, and this demonstrated the robustness of the LC-MS/MS system used in this work. Conclusions A LC-MS/MS method with dual ESI and APCI sources was developed for the analysis of 66 pesticides in hemp. The recovery of all pesticides from a hemp matrix was in the acceptable range of 80-120% with RSD less than 20%.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

3.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据