Permanent pacemaker implantation following transcatheter aortic valve implantation using self-expandable, balloon-expandable, or mechanically expandable devices: a network meta-analysis

期刊

EUROPACE
卷 23, 期 12, 页码 1998-2009

出版社

OXFORD UNIV PRESS
DOI: 10.1093/europace/euab209

关键词

Transcatheter aortic valve implantation; Permanent pacemaker implantation; Devices; Mechanically expandable valve; Balloon-expandable valve; Self-expandable valve; Meta-analysis

向作者/读者索取更多资源

The study suggests that using balloon-expandable valves and self-expandable valves in TAVI can reduce the rate of post-TAVI permanent pacemaker implantation, while mechanically expandable valves increase the rate. A personalized approach to patient treatment including device characteristics may help reduce post-TAVI permanent pacemaker implantation and allow TAVI to expand to younger patients.
Aims Permanent pacemaker implantation (PPI) still limits the expansion of indications for transcatheter aortic valve implantation (TAVI). Comparison between different systems remains scarce. We aimed to determine the impact of the device type used on post-TAVI PPI. Methods and results A systematic literature review was performed to identify studies reporting the use of balloon-expandable valve (BEV), self-expandable valve (SEV), and mechanically expandable valve (MEV) and post-TAVI PPI. A network meta-analysis was used to compare TAVI mechanisms (Analysis A) and transcatheter heart valves (Analysis B) with respect to post-TAVI PPI. Analysis A included 40 181 patients with a pooled PPI rate of 19.2% in BEV, 24.7% in SEV, and 34.8% in MEV. Balloon-expandable valve showed lower risk compared to either SEV or MEV and SEV demonstrated lower risk for PPI than MEV. Implantation of BEV was associated with 39% and 62% lower PPI rate with respect to SEV and MEV. Implantation of SEV was associated with 38% lower PPI rate with respect to MEV. Analysis B included 36.143 patients with the lowest pooled PPI rate of 9.6% for Acurate Neo or others, and the highest pooled PPI rate of 34.3% for Lotus. CoreValve, Evolut Portico, and Lotus influenced significantly PPI rate, while Sapien group did not. Conclusion Implantation of BEV and also SEV were associated with lower post-TAVI PPI rate, while MEV were associated with higher post-TAVI PPI. Patient tailored-approach including devices characteristics may help to reduce post-TAVI PPI and to allow TAVI to take the leap towards extension of use in younger patients. [GRAPHICS] .

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据