4.6 Article

Multicenter study evaluating one multiplex RT-PCR assay to detect SARS-CoV-2, influenza A/B, and respiratory syncytia virus using the LabTurbo AIO open platform: epidemiological features, automated sample-to-result, and high-throughput testing

期刊

AGING-US
卷 13, 期 23, 页码 24931-24942

出版社

IMPACT JOURNALS LLC

关键词

COVID-19; SARS-CoV-2; B.1.1.7 variant; multiplex testing; SARS-CoV-2 VOC

资金

  1. Tri-Service General Hospital, Taipei, Taiwan, ROC [TSGH-D-110100]

向作者/读者索取更多资源

This study aimed to evaluate the performance and analytical sensitivity of the LabTurbo AIO 48 system for SARS-CoV-2, influenza A/B, and RSV using 652 nasopharyngeal swab clinical samples. The system demonstrated consistent performance and high sensitivity in detecting these viruses, suggesting its potential for streamlined testing in the future. The multiplex RT-PCR on the LabTurbo AIO 48 open platform provided highly sensitive, robust, and accurate results for detecting B.1.1.7, influenza A/B, and RSV efficiently.
Since the Coronavirus 19 (COVID-19) pandemic, several SARS-CoV-2 variants of concern (SARS-CoV-2 VOC) have been reported. The B.1.1.7 variant has been associated with increased mortality and transmission risk. Furthermore, cluster and possible co-infection cases could occur in the next influenza season or COVID-19 pandemic wave, warranting efficient diagnosis and treatment decision making. Here, we aimed to detect SARS-CoV-2 and other common respiratory viruses using multiplex RT-PCR developed on the LabTurbo AIO 48 open system. We performed a multicenter study to evaluate the performance and analytical sensitivity of the LabTurbo AIO 48 system for SARS-CoV-2, influenza A/B, and respiratory syncytial virus (RSV) using 652 nasopharyngeal swab clinical samples from patients. The LabTurbo AIO 48 system demonstrated a sensitivity of 9.4 copies/per PCR for N2 of SARS-CoV-2; 24 copies/per PCR for M of influenza A and B; and 24 copies/per PCR for N of RSV. The assay presented consistent performance in the multicenter study. The multiplex RT-PCR applied on the LabTurbo AIO 48 open platform provided highly sensitive, robust, and accurate results and enabled high-throughput detection of B.1.1.7, influenza A/B, and RSV with short turnaround times. Therefore, this automated molecular diagnostic assay could enable streamlined testing if COVID-19 becomes a seasonal disease.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据