The study demonstrated that the Indian-manufactured SII-ChAdOx1 nCoV-19 vaccine is comparable to the AZD1222 vaccine in terms of immunogenicity and safety, showing good immune response and acceptable safety profile. The study also revealed a low rate of SARS-CoV-2 infections post-vaccination, with no severe adverse events reported.
Background: This phase 2/3 immunobridging study evaluated the safety and immunogenicity of the ChAdOx1 nCoV-19 Coronavirus Vaccine (Recombinant) (SII-ChAdOx1 nCoV-19), manufactured in India at the Serum Institute of India Pvt Ltd (SIIPL), following technology transfer from the AstraZeneca. Methods: This participant-blind, observer-blind study randomised participants 3:1 to SII-ChAdOx1 nCoV-19 or AZD1222 (ChAdOx1 nCoV-19) (immunogenicity/reactogenicity cohort) and 3:1 to SII-ChAdOx1 nCoV-19 or placebo (safety cohort). The study participants were enrolled from 14 hospitals across India between August 25 and October 31, 2020. Two doses of study products were given 4 weeks apart. The primary objectives were to demonstrate non-inferiority of SII-ChAdOx1 nCoV-19 to AZD1222 in terms of geometric mean titre (GMT) ratio of anti-SARS-CoV-2 spike IgG antibodies 28 days after the second dose (defined as lower limit of 95% CI >0.67) and to determine the incidence of serious adverse events (SAEs) causally related to SII-ChAdOx1 nCoV-19. The anti-spike IgG response was assessed using a multiplexed electrochemilumines-cence-based immunoassay. Safety follow-up continued until 6 months after first dose. Trial registration: CTRI/2020/08/027170. Findings: 1601 participants were enrolled: 401 to the immunogenicity/reactogenicity cohort and 1200 to the safety cohort. After two doses, seroconversion rates for anti-spike IgG antibodies were more than 98.0% in both the groups. SII-ChAdOx1 nCoV-19 was non-inferior to AZD1222 (GMT ratio 0.98; 95% CI 0.78-1.23). SAEs were reported in < 2.0% participants across the three groups; none were causally related. A total of 34 SARS-CoV-2 infections were reported; of which 6 occurred more than 2 weeks after the second dose; none were severe. Interpretation: SII-ChAdOx1 nCoV-19 has a non-inferior immune response compared to AZD1222 and an acceptable safety/reactogenicity profile. Pharmacovigilance should be maintained to detect any safety signals. Funding: SIIPL funded the contract research organisation and laboratory costs, while the site costs were funded by the Indian Council of Medical Research. The study vaccines were supplied by SIIPL and AstraZe-neca. (c) 2021 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/)

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据