期刊
RESULTS IN ENGINEERING
卷 12, 期 -, 页码 -出版社
ELSEVIER
DOI: 10.1016/j.rineng.2021.100312
关键词
Lipid membrane biosensor; Self-assembly; Horseradish peroxidase; Water monitoring; Hydrogen peroxide
The study introduces a peroxide biosensor based on a metal-supported, self-assembled lipid membrane incorporated with horseradish peroxidase, demonstrating good analytical and operational characteristics, as well as reliable performance in real water samples.
This work presents a simple, low-cost and ready-to-use peroxide biosensor based on a metal-supported, self assembled lipid membrane incorporated with horseradish peroxidase. The peroxide sensor showed good analytical and operational characteristics: the detection limit (as S/N = 3) was 0.083 mu M and the sensitivity was 1.4071 nA per mu M of analyte concentration. The sensor was stable (<5% drift) for 9 h of continuous operation. The validation in real water samples showed that the sensor could reliably detect 0.95 mM of hydrogen peroxide in tap, river and lake water. The reliability of the sensor has been also proven on commercial peroxide formulations, assayed without pretreatment. The prospects and applicability of the proposed biosensor and the underlying technology are also discussed.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐