4.3 Article

Evaluation of various preservation media for storage of donor corneas

期刊

INDIAN JOURNAL OF OPHTHALMOLOGY
卷 69, 期 9, 页码 2452-2456

出版社

WOLTERS KLUWER MEDKNOW PUBLICATIONS
DOI: 10.4103/ijo.IJO_258_21

关键词

Corneal preservation; Cornisol medium; donor corneal storage; MK medium; Optisol-GS medium

向作者/读者索取更多资源

This study compared the physical and microbiological characteristics of three different corneal storage media, and found that Optisol-GS and Cornisol were better at preserving endothelial cell density and stabilizing corneal thickness compared to MK medium. The functional outcomes, however, were comparable among the three groups.
Purpose: To compare the physical and microbiological characteristics of McCarey-Kaufman (MK), Cornisol, and Optisol-GS media and evaluate the outcomes of keratoplasty performed using corneas stored in these three media. Methods: The study involved 60 donor corneas which were distributed in 3 groups: MK, Cornisol, and Optisol-GS. Corneas in these groups were further analyzed based on the type of keratoplasty performed (full thickness versus endothelial keratoplasty). At baseline, the endothelial cell density and death to preservation time of donor corneas were recorded. Following keratoplasty, patients were evaluated on day 1, at 1 month, 3 months, and 6 months follow-up. Outcomes were assessed in terms of corrected distance visual acuity (CDVA), endothelial cell density, percentage endothelial cell loss, and corneal thickness. The storage media were also assessed for their physical quality and their microbiological characteristics. Results: Physical characteristics of all three media were found to be within normal limits. Mean CDVA was comparable among the 3 groups at 6-month follow-up. The absolute endothelial cell count values were significantly lower for corneas stored in MK medium (1873.7 +/- 261.1 cells/mm(2)) compared to the Cornisol (2085.0 +/- 230.3 cells/mm(2)) and Optisol-GS media [(2180.3 +/- 217.2 cells/mm(2)) (P = <0.001)]. Corneas stored in Optisol-GS medium were significantly thinner at 1-month follow-up with no significant difference at 6 months (P = 0.66). Conclusion: Optisol-GS and Cornisol media were found to preserve endothelial cell density better and stabilize corneal thickness earlier as compared to the MK medium. However, the functional outcomes were comparable among the three groups.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据