期刊
ENERGY
卷 141, 期 -, 页码 1187-1203出版社
PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.energy.2017.09.063
关键词
Concentrated solar power (CSP); Parabolic trough collector; Thermal model; Experiments; Transient behavior
资金
- Agence Nationale de la Recherche (National Agency for Research) of the French State [ANR-10-EQPX-49-SOCRATE, ANR-10-LABX-22-01]
This work aims to predict the general performances of a pilot parabolic trough collector during transient periods. To do so, a one-dimensional thermal model has been developed. It has been validated with experimental results from two different experimental setups, in steady-state conditions, with a transmitted power maximum error of 3.4%. Since the model only predicts the collector's thermal behavior, the parabolic trough collector has been first optically qualified. Then, optical efficiencies were used as input for the model. Experimental results were obtained in steady-state conditions and compared to the model. Then, experimental and numerical results were compared during two period of time with varying inlet conditions (i.e. dynamic condition tests): the first one with stable conditions, and the other one with harsh conditions. The developed model showed a good capability of predicting the thermal behavior of the parabolic trough collector with unstable environment (DNI, mass flow, inlet temperature), with a 9.6% relative standard error in the worst case. As a conclusion, while previous studies only focused on steady-state conditions, it has been showed that this kind of model can be used to precisely predict the dynamic behavior of large power plants. (C) 2017 Elsevier Ltd. All rights reserved.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐