3.9 Review

Analysis of the Exeter V40 femoral stem prosthesis fracture SYSTEMATIC REVIEW AND SINGLE CENTRE CASE SERIES

期刊

BONE & JOINT OPEN
卷 2, 期 6, 页码 433-446

出版社

BRITISH EDITORIAL SOC BONE & JOINT SURGERY
DOI: 10.1302/2633-1462.26.BJO-2021-0025.R1

关键词

V40; Exeter; Failure; fracture; stem; incidence

资金

  1. Trauma & Orthopaedics department at Norfolk
  2. Norwich University Hospital NHS Foundation Trust

向作者/读者索取更多资源

The Exeter V40 cemented polished tapered stem system has excellent long-term outcomes, but the risk of stem fractures is higher in revision arthroplasty patients and with 125 mm length stems compared to longer stems. Short 125 mm V40 stems are associated with stem-body fractures, earlier time to fracture, younger patient age, and female sex.
Aims The Exeter V40 cemented polished tapered stem system has demonstrated excellent long-term outcomes. This paper presents a systematic review of the existing literature and reports on a large case series comparing implant fractures between the Exeter V40 series; 125 mm and conventional length stem systems. Methods A systematic literature search was performed adhering to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) criteria. In parallel, we performed a retrospective single centre study of Exeter V40 femoral stem prosthetic fractures between April 2003 and June 2020. Results There are 25 reported cases of such prosthetic fractures confined to small case series and case reports within the literature. We report an additional 19 cases to the literature (mean age 66.3 years (SD 11.7); 12 (63%) females; BMI 32.9 kg/m(2) (SD 5.9)). The mean time from index procedure to fracture was 7.8 years (SD 3.6; 2.5 to 16.3). Exeter V40 stem fracture incidence was 0.15% and 1.21% for primary and revision arthroplasty, respectively. Incidence was significantly higher in revision arthroplasty (p < 0.001) and 125 mm length stems compared to >= 150 mm length stems (1.25% vs 0.13%, respectively; p < 0.001). When comparing different stem length cohorts, 125 mm short-stems were associated with stem-body fractures (92% vs 29%; p = 0.0095), earlier time to fracture (6.2 years vs 11.0 years; p = 0.0018), younger patient age at time of fracture (62.7 years vs 72.6 years; p = 0.037), and female sex (75% vs 43%; p = 0.326). Conclusion This complication remains rare, although we report a significantly higher incidence at up to 17 years follow-up than in the literature. Short 125 mm length Exeter V40 stems undoubtedly have a role in restoring anatomy and biomechanics in smaller femoral geometries, although the surgeon has to appreciate the higher risk of stem fracture and the associated predisposing factors which may necessitate particular attention to surgical technique and planning.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

3.9
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据