3.8 Proceedings Paper

Impact of the Transformer Magnetizing Inductance on the Performance of the Dual-Active Bridge Converter

出版社

IEEE
DOI: 10.1109/COMPEL52922.2021.9645978

关键词

DAB; modeling; magnetizing inductance; dual-active bridge converter; soft-switching

资金

  1. Solar Energy Technologies Office of U.S. Department of Energy
  2. U.S. Department of Energy's Office of Energy Efficiency and Renewable Energy (EERE) under the Solar Energy Technologies Office [34019]
  3. U.S. Department of Energy [EE0002064]
  4. DOE Public Access Plan

向作者/读者索取更多资源

This paper analyzes the operation and performance of the DAB converter with consideration of transformer magnetizing inductance, and shows that it impacts the soft-switching region, power transfer capability, and leakage inductor current. A simulation case study and experimental validation with a DAB converter prototype are provided to verify the analysis.
The magnetizing inductance of the high-frequency transformer in the dual-active bridge (DAB) converter is usually assumed to be much larger than its leakage inductance, thereby the magnetizing current can be negligible. However, ignoring the magnetizing current will lead to an error in the DAB converter design process. This paper analyzes the operation and performance of the DAB converter for a general case in which the transformer magnetizing inductance is taken into consideration. The analysis shows that the magnetizing inductance impacts the soft-switching region, the power transfer capability, and the leakage inductor current. A simulation case study is provided to verify the analysis. A DAB converter prototype is built to experimentally validate the analysis as well.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

3.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据