The noninvasive and optical only glucose monitoring investigation and analysis

出版社

IEEE
DOI: 10.1109/I2MTC50364.2021.9459869

关键词

optical path lengths; laser diode powers; precipitation times of glucose; noninvasive optical only glucose monitoring

资金

  1. Ministry of Science and Technology (MOST) in Taiwan (R. O. C.) [MOST108-2622-E-492-025-CC3]

向作者/读者索取更多资源

Regular glucose monitoring is essential in preventive medicine to detect diseases early, and noninvasive optical glucose sensors offer user-friendly advantages. Near-infrared (NIR) sensors are popular for their analysis based on glucose properties. Experiment results show that shorter optical path lengths and higher laser powers are optimal for discriminating glucose levels in noninvasive monitoring.
For preventive medicine, regular glucose monitoring is the potential production to detect the possibility of diseases at an early stage. The noninvasive and optical only glucose sensor is more user-friendly for customers because of the advantages of small size, low cost, and easy operation. The near-infrared (NIR) glucose sensor is the most popular analytic method based on the glucose properties of overtones and combinational bands. For hardware setup, the 3D printing machine was used to fabricate the assembly components including the sample cuvette structure, the sample holder, and the laser diode stage, etc. The sample cuvette was composed of the structure with two square glasses with optical path length of 1, 1.5, 2 mm, and the optical component include the 1456 nm laser diode and the PD (photodiode). This paper investigates the glucose precipitation experiment (0-90 min), the response voltages with the different optical path lengths (1, 1.5, and 2 mm), and the response voltages with the laser power was 574, 798, 950, and 1045 mW/cm(2) according to Beer-Lambert law, respectively. In the results, the different response voltages had not different when the precipitation time less than 90 min. In addition, the concentration of the glucose solution with the same optical path length and the same laser power was proportional to the response voltage. The optical path length with the same concentration of the glucose solution and the same laser power was inversely proportional to the response voltage. The laser power with the same optical path length and the same concentration of the glucose solution was proportional to the response voltage. The 1 mm optical path length and the 1045 mW/cm(2) laser power had the best discrimination than the other optical path lengths and the other laser powers. The experiment results indicate that the shortest optical path length and the largest laser power are required for the best discrimination of the noninvasive and optical only glucose monitoring production.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

3.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据