4.5 Article

Robotic-assisted TKA leads to a better prosthesis alignment and a better joint line restoration as compared to conventional TKA: a prospective randomized controlled trial

期刊

出版社

SPRINGER
DOI: 10.1007/s00167-020-06353-2

关键词

Robotic; Conventional; Total knee arthroplasty; Mechanical axis; Joint line; Coronal alignment; Handheld burr; Haptic feedback; Semi-active system

向作者/读者索取更多资源

The study found that the new semi-active robotic-assisted total knee arthroplasty is more accurate than conventional TKA in terms of mechanical axis deviation, joint line deviation, and coronal alignment of femoral and tibial prosthesis. However, the impact of joint line elevation difference on knee kinematics and flexion between conventional and robotic-assisted TKA requires further investigation.
Purpose Correct positioning and alignment of the prosthesis is a very important factor for durability of prosthesis and implant survival which is improved with the use of technology in total knee arthroplasty. However, the long-term functional outcomes and survivorship are unclear. For this study, it was hypothesized that mechanical axis alignment of lower limb, post-operative joint line restoration, femoral and tibial component alignment is more accurate with the new handheld semi-active robotic-assisted TKA. Method From April-2019 to March-2020, 60 patients with unilateral knee osteoarthritis who underwent total knee arthroplasties were included in this prospective randomised controlled study. Computer generated randomization was used. Study included 48 female patients and 12 male patients. Pre-operative and post-operative radiographic measurements were done and compared between the two groups. Results There was a significant difference between two groups with respect to mechanical axis deviation, joint line deviation and coronal alignment of femoral and tibial prosthesis. Mechanical axis deviation > 3 degrees was seen in eight cases (28.5%) in C-TKA group compared to one case (3.1%) in RA-TKA (p 0.019). Joint line deviation of 3.5 mm was noted in C-TKA group as compared to 0.9 mm in RA-TKA group (p < 0.001) which was statistically significant. However, whether this difference of 2.6 mm of joint line elevation between C-TKA and RA-TKA leads to any difference in clinical outcome in terms of knee kinematics and knee flexion needs to be investigated with further studies. Clinically restoring normal joint line is important for improved knee function after primary TKA. No significant difference was noted in femoral component rotation on post-operative computed tomography (CT) scan. Conclusion The novel imageless, handheld semi-autonomous robotic system for TKA is highly accurate with respect to component positioning in coronal plane and mechanical alignment as compared to conventional TKA. Joint line is elevated in conventional TKA but is accurately restored using the robotic-assisted TKA which may lead to better patellofemoral kinematics.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据