4.5 Article

Neural Network and Fuzzy Control Based 11-Level Cascaded Inverter Operation

期刊

CMC-COMPUTERS MATERIALS & CONTINUA
卷 70, 期 2, 页码 2319-2346

出版社

TECH SCIENCE PRESS
DOI: 10.32604/cmc.2022.019559

关键词

Ultra-capacitor; 11-level cascaded H-bridge inverter; hybrid energy system; modified perturb and observer; neural network-based PI; fuzzy controller

资金

  1. Council of scientific and industrial research (CSIR)

向作者/读者索取更多资源

This paper presents a combined control and modulation technique using a single-phase 11-level cascaded H-bridge inverter to enhance the power quality and power reliability of a hybrid energy system. The technique employs a Modified Perturb and Observe technique to track optimum power and proposes an ultra-capacitor-based energy storage device and a novel current control strategy to provide additional active power support during voltage sag and swell conditions. A two-way current control strategy and a hybrid pulse width modulation technique are suggested for improved power quality and reliability. The robust controller performance is tested using MATLAB/Simulink software-based designed model.
This paper presents a combined control and modulation technique to enhance the power quality (PQ) and power reliability (PR) of a hybrid energy system (HES) through a single-phase 11-level cascaded H-bridge inverter (11CHBI). The controller and inverter specifically regulate the HES and meet the load demand. To track optimum power, a Modified Perturb and Observe (MP&O) technique is used for HES. Ultra-capacitor (UCAP) based energy storage device and a novel current control strategy are proposed to provide additional active power support during both voltage sag and swell conditions. For an improved PQ and PR, a two-way current control strategy such as the main controller (MC) and auxiliary controller (AC) is suggested for the 11CHBI operation. MC is used to regulate the active current component through the fuzzy controller (FC), and AC is used to regulate the dc-link voltage of CHBI through a neural network-based PI controller (ANN-PI). By tracking the reference signals from MC and AC, a novel hybrid pulse width modulation (HPWM) technique is proposed for the 11-CHBI operation. To justify and analyze the MATLAB/Simulink software-based designed model, the robust controller performance is tested through numerous steady-state and dynamic state case studies.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据