4.5 Article

A Bioprinted Heart-on-a-Chip with Human Pluripotent Stem Cell-Derived Cardiomyocytes for Drug Evaluation

期刊

BIOENGINEERING-BASEL
卷 9, 期 1, 页码 -

出版社

MDPI
DOI: 10.3390/bioengineering9010032

关键词

cell-printing; organs-on-a-chips; bio-ink; hydrogels; hiPSC-CMs; in vitro testing; drug screening

资金

  1. Government of Extremadura [TA18014]
  2. EPSRC [EP/M506837/1, EP/P511420/1]
  3. Innovate UK
  4. NC3Rs (Advancing the development and application of non-animal technologies programme)
  5. EPSRC [EP/M506837/1] Funding Source: UKRI

向作者/读者索取更多资源

In this study, it was found that valve-based bioprinting had no measurable detrimental effects on human-induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs). The use of bio-ink droplets containing a liquid suspension of live cardiomyocytes was proven to be an alternative to standard manual handling and could reduce the number of cells required for drug testing, with no significant differences in drug-sensitivity between both approaches.
In this work, we show that valve-based bioprinting induces no measurable detrimental effects on human-induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs). The aim of the current study was three-fold: first, to assess the response of hiPSC-CMs to several hydrogel formulations by measuring electrophysiological function; second, to customise a new microvalve-based cell printing mechanism in order to deliver hiPSC-CMs suspensions, and third, to compare the traditional manual pipetting cell-culture method and cardiomyocytes dispensed with the bioprinter. To achieve the first and third objectives, iCell(2) (Cellular Dynamics International) hiPSC-CMs were used. The effects of well-known drugs were tested on iCell(2) cultured by manual pipetting and bioprinting. Despite the results showing that hydrogels and their cross-linkers significantly reduced the electrophysiological performance of the cells compared with those cultured on fibronectin, the bio-ink droplets containing a liquid suspension of live cardiomyocytes proved to be an alternative to standard manual handling and could reduce the number of cells required for drug testing, with no significant differences in drug-sensitivity between both approaches. These results provide a basis for the development of a novel bioprinter with nanolitre resolution to decrease the required number of cells and to automate the cell plating process.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据