期刊
LANCET DIGITAL HEALTH
卷 4, 期 2, 页码 E105-E116出版社
ELSEVIER
关键词
-
资金
- German Centre for Cardiovascular Research (DZHK)
- Medtronic Bakken Research Center
Telemedical monitoring with implantable cardiac monitors can improve early detection of subclinical but prognostically relevant arrhythmic events in patients with cardiac autonomic dysfunction after myocardial infarction and moderately reduced left ventricular ejection fraction.
Background Cardiac autonomic dysfunction after myocardial infarction identifies patients at high risk despite only moderately reduced left ventricular ejection fraction. We aimed to show that telemedical monitoring with implantable cardiac monitors in these patients can improve early detection of subclinical but prognostically relevant arrhythmic events. Methods We did a prospective investigator-initiated, randomised, multicentre, open-label, diagnostic trial at 33 centres in Germany and Austria. Survivors of acute myocardial infarction with left ventricular ejection fraction of 36-50% had biosignal analysis for assessment of cardiac autonoinic function. Patients with abnormal periodic repolarisation dynamics (>= 5.75 deg(2)) or abnormal deceleration capacity (<= 2.5 ms) were randomly assigned (1:1) to telemedical monitoring with implantable cardiac monitors or conventional follow-up. Primary endpoint was time to detection of serious arrhythmic events defined by atrial fibrillation 6 min or longer, atrioventricular block class IIb or higher and fast non-sustained (>187 beats per min; >= 40 beats) or sustained ventricular tachycardia or fibrillation. This study is registered with ClinicalTrials.gov, NCT02594488. Findings Between May 12, 2016, and July 20, 2020, 1305 individuals were screened and 400 patients at high risk were randomly assigned (median age 64 years [IQR 57-73]); left ventricular ejection fraction 45% [40-48]) to telemedical monitoring with implantable cardiac monitors (implantable cardiac monitor group; n=201) or conventional follow-up (control group; n=199). During median follow-up of 21 months, serious arrhythmic events were detected in 60 (30%) patients of the implantable cardiac monitor group and 12 (6%) patients of the control group (hazard ratio 6.33 [IQR 3.40-11.78]; p<0.001). An improved detection rate by implantable cardiac monitors was observed for all types of serious arrhythmic events: atrial fibrillation 6 min or longer (47 [23%] patients vs 11 [16%] patients; p<0.001), atrioventricular block class IIb or higher (14 [7%] vs 0; p<0.001) and ventricular tachycardia or ventricular fibrillation (nine [4%] patients vs two [1%] patients; p=0.054). Interpretation In patients at high risk after myocardial infarction and cardiac autonomic dysfunction but only moderately reduced left ventricular ejection fraction, telemedical monitoring with implantable cardiac monitors was highly effective in early detection of subclinical, prognostically relevant serious arrhythmic events. Copyright (C) 2022 The Author(s). Published by Elsevier Ltd.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐
暂无数据