4.6 Article

Diagnosis of Myocardial Infarction Using a High-Sensitivity Troponin I 1-Hour Algorithm

期刊

JAMA CARDIOLOGY
卷 1, 期 4, 页码 397-404

出版社

AMER MEDICAL ASSOC
DOI: 10.1001/jamacardio.2016.0695

关键词

-

资金

  1. German Center of Cardiovascular Research
  2. Abbott Diagnostics (Biomarkers in Acute Cardiac Care [BACC] trial)
  3. Queensland Emergency Medicine Foundation

向作者/读者索取更多资源

IMPORTANCE Rapid and accurate diagnosis of acutemyocardial infarction (AMI) currently constitutes an unmet need. OBJECTIVE To test a 1-hour diagnostic algorithm to diagnose AMI using a high-sensitivity troponin I assay with a new cutoff level of 6 ng/L. DESIGN, SETTING, AND PARTICIPANTS The Biomarkers in Acute Cardiac Care study is a prospective study that investigated the application of the troponin I assay for the diagnosis of AMI in 1040 patients presenting to the emergency department with acute chest pain from July 19, 2013, to December 31, 2014. Results were validated in 2 independent cohorts of 4009 patients. Final follow-up was completed on July 1, 2015, and data were assessed from July 2 to December 15, 2015. EXPOSURE Acute chest pain suggestive of AMI. MAIN OUTCOMES AND MEASURES Accurate diagnosis or exclusion of AMI and 12-month mortality in patients with acute chest pain. RESULTS Of the 1040 patients included from the study cohort, 673 (64.7%) were male and had a median age of 65 (interquartile range, 52-75) years. With application of a low troponin I cutoff value of 6 ng/L, the rule-out algorithm showed a high negative predictive value of 99.8%(95% CI, 98.6%-100.0%) after 1 hour for non-ST-segment elevation MI type 1. The 1-hour approach was comparable to a 3-hour approach. Similarly, a rule-in algorithm based on troponin I levels provided a high positive predictive value with 82.8%(95% CI, 73.2%-90.0%). Moreover, application of the cutoff of 6 ng/L resulted in lower follow-up mortality (1.0%) compared with the routinely used 99th percentile (3.7%) for this assay. Two independent cohorts further validated the performance of this algorithm with high negative and positive predictive values. CONCLUSIONS AND RELEVANCE Patients with possible AMI can be triaged within 1 hour after admission with no loss of safety compared with a 3-hour approach, when a low and sensitive cutoff is applied. This concept enables safe discharge or rapid treatment initiation after 1 hour.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据