3.8 Article

Patient radiation dose during angiography and embolization for abdominal hemorrhage: the influence of CT angiography, fluoroscopy system, patient and procedural variables

期刊

CVIR ENDOVASCULAR
卷 5, 期 1, 页码 -

出版社

SPRINGERNATURE
DOI: 10.1186/s42155-022-00284-4

关键词

Angiography; Abdominal; embolisation; Humans; Hemorrhage; Radiation dose; Gastrointestinal; Safety

向作者/读者索取更多资源

New fluoroscopic technology significantly reduces the radiation dose of angiography and embolization for abdominal arterial hemorrhage. The patient's body mass index is a key factor affecting the dose, while the bleeding site and the performance of pre-procedure CT angiography do not influence the radiation dose.
Background Angiography and embolization (AE) is a lifesaving, high radiation dose procedure for treatment of abdominal arterial hemorrhage (AAH). Interventional radiologists have utilized pre-procedure CT angiography (CTA) and newer fluoroscopic systems in an attempt to reduce radiation dose and procedure time. Purpose To study the factors contributing to the radiation dose of AE for AAH and to compare to the reference standard. Materials and methods This retrospective single-centre observational cohort study identified 154 consecutive AE procedures in 138 patients (median age 65 years; interquartile range 54-77; 103 men) performed with a C-arm fluoroscopic system (Axiom Artis DTA or Axiom Artis Q (Siemens Healthineers)), between January 2010 and December 2017. Parameters analysed included: demographics, fluoroscopy system, bleeding location, body mass index (BMI), preprocedural CT, air kerma-area product (PKA), reference air kerma (K-a,K-r), fluoroscopy time (FT) and the number of digital subtraction angiography (DSA) runs. Factors affecting dose were assessed using Mann-Whitney U, Kruskal-Wallis one-way ANOVA and linear regression. Results Patients treated with the new angiographic system (NS) had a median PKA, median K-a,K-r, Q3 PKA and Q3 K-a,K-r that were 74% (p < 0.0005), 66%(p < 0.0005), 55% and 52% lower respectively than those treated with the old system (OS). This dose reduction was consistent for each bleeding location (upper GI, Lower GI and extraluminal). There was no difference in PKA (p = 0.452), K-a,K-r (p = 0.974) or FT (p = 0.179), between those who did (n = 137) or did not (n = 17) undergo pre-procedure CTA. Other factors significantly influencing radiation dose were: patient BMI and number of DSA runs. A multivariate model containing these variables accounts for 15.2% of the variance in K-a,K-r (p < 0.005) and 45.9% of the variance of PKA (p < 0.005). Conclusion Radiation dose for AE in AAH is significantly reduced by new fluoroscopic technology. Higher patient body mass index is an independent key parameter affecting patient dose. Radiation dose was not influenced by haemorrhage site or performance of pre-procedure CTA.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

3.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据