4.0 Article

Valve-in-Valve Implantation of Medtronic CoreValve Prosthesis in Patients With Failing Bioprosthetic Aortic Valves: Mid-term Outcomes From the Italian CoreValve Clinical Service Project

期刊

JOURNAL OF INVASIVE CARDIOLOGY
卷 34, 期 2, 页码 E73-E79

出版社

H M P COMMUNICATIONS

关键词

perivalvular regurgitation; snorkel stenting; transcatheter aortic valve replacement; valve-in-valve

向作者/读者索取更多资源

This study evaluated the acute and two-year safety and efficacy of using the Corevalve, Evolut R, and Evolut PRO valves for treating failed surgical bioprosthesis from the Italian CoreValve Clinical Service Project. The results demonstrated that these valves were safe and effective in the short-term and long-term.
Objectives. We evaluated the acute and two-year safety and efficacy of using the Corevalve, Evolut R, and Evolut PRO valves for treating failed surgical bioprosthesis from the Italian CoreValve Clinical Service Project. Background. Valve-in-valve (ViV) TAVR is an emerging treatment option for failed surgical bioprosthesis. Choice of transcatheter valve is an important determinant of procedural and clinical outcomes, however, longer-term data are lacking. Methods. The Clinical Service Project is a national clinical data repository evaluating the use of implantable devices across Italy. The present multi-center analysis includes consecutive patients who underwent ViV-TAVR with the Medtronic CoreValve series between October 2008 to June 2019. Evaluated endpoints included rates of overall mortality, cardiovascular mortality, myocardial infarction, and cerebrovascular accidents at 2-year follow-up. Procedural success, complications, and echocardiographic outcomes were reported according to VARC-2 criteria. Results. A total of 139 patients (mean age, 80 +/- 7 years; 47.5% male; mean STS score, 10.0 +/- 9.7%) underwent ViV-TAVR with CoreValve (28.5%), Evolut R (68.6%), and Evolut Pro (2.9%) valves. Device success was achieved in 68% and acute coronary obstruction requiring PCI was observed in 4 patients (2.9%). Moderate PVL was observed in 3.7% and 2.8% of patients at 30-day and 2-year follow-up and moderate structural valve degeneration seen only 5 patients (3.6%). All-cause and cardiovascular mortality were 3.6% and 2.9% at 30 days, respectively, and 20.6% and 10.2% at 2-year follow-up. Conclusions. This real-world nationwide analysis demonstrates the acute and longer-term safety and efficacy of using the self-expanding Medtronic THV for ViV-TAVR.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.0
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据