4.6 Article

Comparison of point shear wave elastography and transient elastography in the evaluation of patients with NAFLD

期刊

RADIOLOGIA MEDICA
卷 127, 期 5, 页码 571-576

出版社

SPRINGER-VERLAG ITALIA SRL
DOI: 10.1007/s11547-022-01475-8

关键词

Point shear wave elastography; Transient elastography; Liver stiffness; Non-alcoholic fatty liver disease; Liver biopsy

向作者/读者索取更多资源

This study compared the diagnostic accuracy of point shear wave elastography (pSWE) and transient elastography (TE) in evaluating fibrosis stage in non-alcoholic fatty liver disease (NAFLD). The results showed that TE was significantly better than pSWE in diagnosing fibrosis stage >= F2, while there were no significant differences between TE and pSWE in diagnosing fibrosis stage >= F1, >= F3, and F4.
Purpose To compare point shear wave elastography (pSWE, ElastPQ (R)) and transient elastography (TE) with Liver Biopsy in order to evaluate fibrosis stage in non-alcoholic fatty liver disease (NAFLD). Methods Our prospective study from September 2017 to October 2020 included 50 consecutively enrolled patients with NAFLD (52.2 +/- 13.0 years, 32 male). All patients underwent clinical evaluation, B-mode ultrasound, pSWE, TE and liver biopsy in a single evaluation. The clinical, laboratory and liver biopsy data were compared with liver stiffness (LS) measurement obtained with pSWE and TE. TE and pSWE diagnostic accuracy for the diagnosis of the different fibrosis stages were evaluated using the area under receiver operating characteristic curve (AUROC). Results Only fibrosis stage was independently associated with TE and pSWE. The median liver stiffness measurement for fibrosis stages F0, F1, F2, F3, and F4 using TE was 4.8 (4.7-6.1) kPa, 5.5 (4.4-7.3) kPa, 7.7 (6.1-9.1) kPa, 9.9 (8.8-13.8) kPa, and 20.2 kPa, respectively. The corresponding median liver stiffness measurement using pSWE was 4.2 (4.0-4.8) kPa, 4.7 (4.2-5.8) kPa, 5.1 (4.1-6.9) kPa, 8.5 (5.2-13.3), and 15.1 kPa, respectively. The AUROC of TE for diagnosis of fibrosis stage F1, >= F2, >= F3, and F4 were 0.795, 0.867, 0.927, and 0.990, respectively. The corresponding AUROC of pSWE was 0.717, 0.733, 0.908, and 1.000, respectively. No association was observed with other histological parameters. Conclusion TE was significantly better than pSWE for the diagnosis of fibrosis stage >= F2. No statistically significant differences were found between TE and pSWE AUROC of fibrosis stage >= F1, >= F3, and F4.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据