向作者/读者索取更多资源

This study simulated the clean phase of one-step exchanges in infected total hip arthroplasty (THA). The results showed that a clean phase with full additional measures significantly reduced contamination on gloves, instrument table, drapes, and wound. However, the re-implanted implants still had some level of contamination.
Purposes A septic revision of an artificial joint is routinely split up in a so-called dirty phase and a clean phase. The measures taken to initiate the start of the clean phase vary significantly between musculoskeletal infection centers. We performed simulations of one-step exchanges of infected THAs and sought to 1) determine the effect of different clean phase protocols on the sterile field, and 2) determine whether or not it is possible to re-implant the new prosthesis completely clean. Methods Nine fresh frozen cadaveric hips were used and primary THA was undertaken via a direct anterior approach. Before implantation of the components varying amounts of fluorescent powder (GloGerm) were deposited, simulating bacterial infection. Second, a one-step exchange was performed via a posterolateral approach. After implant removal, debridement, and lavage, randomization determined which clean phase protocol was followed, i.e. no, some or full additional measures. Finally, the new prosthesis was re-implanted. In order to determine the effect of different clean phase protocols on contamination of the sterile field standardized UV light-enhanced photographs were obtained of 1) the gloves, 2) the instrument table, 3) the drapes, and 4) the wound and these were ranked on cleanliness by a blinded panel of hip surgeons. In order to determine whether or not it is possible to re-implant the prosthesis completely clean, the implant was taken out again at the end of the one-step exchange and inspected for contamination under UV light. Results The gloves, the instrument table, the drapes and the wound were significantly cleaner after a clean phase using full additional measures compared to partial or no additional measures (p < 0.000). Partial measures were able to reduce some of the contamination of the gloves and the wound, but had no effect on the drapes and the instrument table. All re-implanted implants were contaminated with some amount of fluorescent powder at the end of the one-step exchange. Conclusions We advise to incorporate a clean phase with full additional measures into the surgical treatment of prosthetic joint infections, as partial measures seem to be a poor compromise.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

3.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据