3.9 Article

Postoperative monitoring of free flap reconstruction: A comparison of external Doppler ultrasonography and the implantable Doppler probe

期刊

PLASTIC SURGERY
卷 24, 期 1, 页码 11-19

出版社

SAGE PUBLICATIONS INC
DOI: 10.1177/229255031602400108

关键词

Complications; Doppler; External; Free flap; Handheld; Implantable; Internal; Monitoring; Reconstruction

类别

向作者/读者索取更多资源

HYPOTHESIS: The time to detection of vascular compromise and the postoperative time to re-exploration are shorter using the implantable Doppler (ID) probe, thereby resulting in earlier surgical re-exploration and a higher flap salvage rate. METHODS: A single-centre experience with 176 consecutive free flap reconstructions in 167 patients from 2000 to 2008 in a university-based teaching hospital by retrospective chart review is presented. RESULTS : There was a significant difference in overall flap survival (ID 98.0%, external Doppler [ED] 89.3%) and total flap loss (ID 2.0%, ED 10.7%) between the two groups (P=0.03). The difference in flap salvage rate was not significant (ID 90.9%, ED 63.6%; P=0.068). The false-positive (ID 0%, ED 3%; P=0.18) and false-negative rates (ID 0.0%, ED 4.5%; P=1.0) were not significantly different. There was also a lower median postoperative time to re-exploration for the ID group, from 48 h to one week after initial surgery (ID 74.5 h, ED 136.8 h; P=0.05). CONCLUSION: The present analysis revealed a potential benefit for the ID probe in the postoperative monitoring of free tissue transfers.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

3.9
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据