4.6 Article

Study on a photoacoustic spectroscopy trichloromethane gas detection method based on an arched photoacoustic cavity

期刊

ANALYTICAL METHODS
卷 14, 期 15, 页码 1507-1514

出版社

ROYAL SOC CHEMISTRY
DOI: 10.1039/d1ay02072b

关键词

-

资金

  1. Science and Technology Program of Hebei [18273901D]

向作者/读者索取更多资源

This study proposes a new type of arched photoacoustic cavity based on a study of its performance. By comparing different parameters, the optimal structural size is determined. The performance of the arched photoacoustic cavity is significantly improved compared to the traditional cylindrical cavity. A photoacoustic spectroscopy system for detecting chloroform gas is built based on the arched photoacoustic cavity, with a detection sensitivity of 0.28 ppm.
As an important component in photoacoustic spectroscopy gas detection systems, the performance of the photoacoustic cavity directly affects the sensitivity and resolution of the system. Based on a study of photoacoustic cavity performance, a new type of arched photoacoustic cavity is proposed. Finite element simulation software is used for modeling. By comparing the influences of the position and radius of the central sphere, the length and radius of the resonant cavity, and the radius of the buffer chamber on the performance of the photoacoustic cavity, the optimal structural size of the arched photoacoustic cavity is determined. Compared to a traditional cylindrical photoacoustic cavity with the same size, and considering the thermal viscous acoustic loss, a thermal-acoustic coupling multiphysical field simulation of the two models is carried out. The acoustic pressure signal of the arched photoacoustic cavity is 6 times that of the cylindrical photoacoustic cavity, the resonant frequency increases by 300 Hz, and the quality factor is 2.6 times that of the cylindrical photoacoustic cavity. The performance of the arched photoacoustic cavity is significantly improved. A photoacoustic spectroscopy system for the detection of chloroform gas (CHCl3) is built based on an arched photoacoustic cavity. Detection experiments are carried out with different concentrations of chloroform. At room temperature (25 degrees C) and atmospheric pressure, the linear coefficient R-2 is 0.9975, and the detection sensitivity is 0.28 ppm. The system has great practical value for the detection of chloroform gas in industrial and agricultural applications.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据