Comparison of AC and DC Partial Discharge by Monitoring of Vacuum Degree in a Distribution Class Vacuum Interrupter

期刊

IEEE ACCESS
卷 10, 期 -, 页码 36254-36267

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/ACCESS.2022.3163448

关键词

AC; DC; distribution class; dielectric strength; partial discharge; PRPD; PSA; monitoring; maintenance criteria; vacuum interrupter

向作者/读者索取更多资源

This paper compares AC and DC partial discharge by monitoring the vacuum degree of a distribution class Vacuum Interrupter (VI) to propose maintenance criteria according to voltage type. The study finds that maintenance should be performed when the vacuum degree is in the range of 10(-3) to 10(-2) torr regardless of the voltage type, and the technology is more useful at AC voltage than at DC voltage.
The vacuum degree of Vacuum Interrupter (VI) will deteriorate because of gases emitted by arc heat, and leakage through the joints. It is important to select an appropriate maintenance criteria for a VI by monitoring the vacuum degree. However, monitoring of a VI installed inside a solid insulation apparatus in a transmission system is impossible. Only studies on the insulation deterioration because of the decrease of the vacuum degree have been conducted, and important factors such as the maintenance criteria have not been investigated. Moreover, most studies have only been performed using AC voltage, not DC voltage. Therefore, in this paper, AC and DC partial discharge were compared by monitoring of the vacuum degree in a distribution class VI to propose maintenance criteria according to voltage type. Through this, for efficient maintenance, maintenance criteria of VI for each voltage type are presented. The vacuum degree at which the dielectric strength rapidly decreases was confirmed according to voltage type. The coupling capacitor was installed directly on the floating shield of VI. Moreover, to measure the pattern and apparent charge of partial discharge according to the vacuum degree, phase resolved partial discharge (PRPD) for AC partial discharge and pulse sequence analysis (PSA) for DC partial discharge were adopted. It is found that maintenance should be performed when the vacuum degree is in the range of 10(-3) similar to 10(-2) torr regardless of the voltage type. Moreover, the usefulness of the technology is higher at AC voltage than at DC voltage.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据