4.4 Article

Gross Tumor Volume Segmentation for Stage III NSCLC Radiotherapy Using 3D ResSE-Unet

期刊

出版社

SAGE PUBLICATIONS INC
DOI: 10.1177/15330338221090847

关键词

lung cancer; CNNs; auto-segmentation; GTV; radiotherapy

类别

资金

  1. National Natural Science Foundation of China [81972857, 11805025]
  2. Innovative Project of Shapingba Diatrict Chongqing [Jcd202135]

向作者/读者索取更多资源

This paper proposes a 3D CNN model called 3D ResSE-Unet for gross tumor volume segmentation in stage III NSCLC radiotherapy. The model combines residual connection and channel attention mechanisms and uses three-dimensional convolution operation and encoding-decoding structure to extract spatial information of tumors from computed tomography data. The performance of the model is evaluated using a testing set and compared with other models. The results show that 3D ResSE-Unet achieves superior segmentation results with a short time cost.
Introduction: Radiotherapy is one of the most effective ways to treat lung cancer. Accurately delineating the gross target volume is a key step in the radiotherapy process. In current clinical practice, the target area is still delineated manually by radiologists, which is time-consuming and laborious. However, these problems can be better solved by deep learning-assisted automatic segmentation methods. Methods: In this paper, a 3D CNN model named 3D ResSE-Unet is proposed for gross tumor volume segmentation for stage III NSCLC radiotherapy. This model is based on 3D Unet and combines residual connection and channel attention mechanisms. Three-dimensional convolution operation and encoding-decoding structure are used to mine three-dimensional spatial information of tumors from computed tomography data. Inspired by ResNet and SE-Net, residual connection and channel attention mechanisms are used to improve segmentation performance. A total of 214 patients with stage III NSCLC were collected selectively and 148 cases were randomly selected as the training set, 30 cases as the validation set, and 36 cases as the testing set. The segmentation performance of models was evaluated by the testing set. In addition, the segmentation results of different depths of 3D Unet were analyzed. And the performance of 3D ResSE-Unet was compared with 3D Unet, 3D Res-Unet, and 3D SE-Unet. Results: Compared with other depths, 3D Unet with four downsampling depths is more suitable for our work. Compared with 3D Unet, 3D Res-Unet, and 3D SE-Unet, 3D ResSE-Unet can obtain superior results. Its dice similarity coefficient, 95th-percentile of Hausdorff distance, and average surface distance can reach 0.7367, 21.39mm, 4.962mm, respectively. And the average time cost of 3D ResSE-Unet to segment a patient is only about 10s. Conclusion: The method proposed in this study provides a new tool for GTV auto-segmentation and may be useful for lung cancer radiotherapy.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据