How to calibrate luminescent crossover thermometers: a note on quasi-Boltzmann systems

期刊

JOURNAL OF MATERIALS CHEMISTRY C
卷 10, 期 37, 页码 13805-13814

出版社

ROYAL SOC CHEMISTRY
DOI: 10.1039/d2tc01152b

关键词

-

向作者/读者索取更多资源

Luminescent thermometers are potential candidates for remote and non-invasive temperature sensing. Boltzmann thermometers rely on thermal coupling between two excited levels, while other luminescent thermometers rely on interconfigurational crossover between excited state potentials. Guidelines for fitting models and verifying their physical reliability are currently lacking for this class of thermometers.
Luminescent thermometers are potential material candidates for remote and non-invasive temperature sensing by means of a temperature-dependent optical signal. A particularly well-known class of luminescent thermometers are Boltzmann thermometers that rely on thermal coupling between two excited levels from the same configuration. Their thermal coupling kinetics is then governed by multiphonon transitions. A substantial part of potential luminescent thermometers does, however, rely on an interconfigurational crossover between two excited state potentials with differing equilibrium metal-ligand distances such as Cr3+ or Pr3+. These thermometers are often characterized by much higher intrinsic non-radiative coupling rates that allow exploiting a much higher energy gap for high relative sensitivities at appreciably low temperatures. For this class of luminescent thermometers, fitting models are often merely effective and no clear guidelines on how to tune them or how to verify the physical reliability of the fit are available. In this work, we derive a generalized fitting model for luminescent crossover thermometers and demonstrate that they generally follow a quasi-Boltzmann law. We explicitly demonstrate the concepts on the established phosphor SrB4O7 : 0.5% Sm2+. In this compound, Sm2+ can be efficiently excited with blue light and shows intense red D-5(0) -> F-7(J) (J = 0 horizontal ellipsis 6) luminescence above 680 nm and broad-banded 4f(5)5d(1) -> 4f(6)-related luminescence peaking at 585 nm. By additional time-resolved measurements, it is possible to independently assess the expected order of magnitude of the fitting parameters and thus, judge the physical content of the calibration model of a luminescent crossover thermometer. It is finally shown that crossover thermometers are characterized by high relative sensitivities and low-temperature measurement uncertainty at elevated temperatures but their liability toward thermal quenching poses a serious limitation to the dynamic working range of this class of thermometers.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据