- Advanced Research Project of Northwest Institute of Nuclear Technology
This article introduces a method of improving the output voltage amplitude and reliability of a nanosecond pulse generator through power synthesis of modularized Marx circuits with transmission line transformers. Experimental results validate the consistency of output characteristics of multiple Marx modules and demonstrate the feasibility of combining pulses generated from four Marx modules with an optimized transmission line transformer. The generator prototype is capable of achieving a wide range of adjustable voltage amplitudes, fast rise time, and narrow full-width at half-maximum.
In order to further improve the output voltage amplitude and repetitive operation reliability of nanosecond pulse generator (PG) based on avalanche transistor (AT), the method of power synthesis of modularized Marx circuits with transmission line transformer (TLT) is employed in this article. The modified positive 4 x 11-stage Marx circuit introducing base-triggering method is designed and implemented to improve the operation reliability. The triggering synchronization and the consistence of output characteristics of multipleMarx modules with an identical trigger pulse are validated. The feasibility of combining pulses generated from four Marx modules with an optimized four-stage TLT is demonstrated. The influences of the type and quantity of magnetic core and the superimposed stage number of TLT on the output performance of the generator are investigated. The operation characteristics of the generator including output parameters, trigger time-delay, and loop efficiency in the whole working range are evaluated. The experimental results show that the working range of the overall device has been widened significantly with the injection of additional initial carrier. Accordingly, the generator prototype is capable of achieving the output performance with an adjustable voltage amplitude in the range of 7.8-26.7 kV on a matched 300-Omega resistive load and 12.2-38.9 kV on the high-resistance load, respectively, a 10%-90% rise time of 3.6 ns, and a full-width at half-maximum (FWHM) of 12.2 ns. A long-term test with the maximum repetition rate of 3 kHz is conducted to realize high-voltage output and high-frequency operation simultaneously.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐
暂无数据