4.6 Article

Estimation of PM2.5 Concentration Based on Support Vector Regression With Improved Dark Channel Prior and High Frequency Information in Images

期刊

IEEE ACCESS
卷 10, 期 -, 页码 48486-48498

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/ACCESS.2022.3172468

关键词

Air quality monitoring; automatic region of interest selection; high frequency information extraction; improved dark channel; PM2.5 concentration estimation

资金

  1. Ministry of Science and Technology in Taiwan [MOST 110-2637-E-324-002, MOST 110-2221-E-324-012]

向作者/读者索取更多资源

This paper proposes a low-cost and effective approach using image processing schemes to estimate the concentration of PM2.5. The approach consists of four stages and utilizes features extracted from images and relative humidity to build a support vector regression model. Experimental results demonstrate that the proposed method outperforms other methods.
The rapid development of the petrochemical industry has caused great harm to the environment. Fine suspended particles with a diameter of less than 2.5 microns cause serious health problems when inhaled air of high concentration of PM2.5. Therefore, an estimate of the concentration of PM2.5 is sought. However, it generally requires expensive instruments installed in an air quality monitoring station and a professional to operate them. In addition to the expensive cost, the instruments require a high maintenance fee and are restricted by geographical location. To eliminate the difficulty, this paper presents a low-cost and effective approach to estimate the concentration of PM2.5 using image processing schemes. The proposed approach consists of four stages. First, images with different concentrations of PM2.5 were taken and the related relative humidity (RH) was collected. Second, an automatically selected region of interest (RoI) was used to extract two features from an image, namely high-frequency information and transmittance by an improved dark channel. Third, the two extracted features, together with the RH measurement, were used to build a support vector regression (SVR) model. Fourth, the SVR model was applied to estimate the concentration of PM2.5, whose performance was then evaluated and compared with four simple regression models and a modified reported SVR method. In the given data set, the proposed method outperforms the comparison methods in terms of R-2 and root mean squared error. The best performance of our method reaches R-2 =0.816 which is generally satisfactory in related applications.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据