4.7 Article

Maximizing the thermal performance index applying evolutionary multi-objective optimization approaches for double pipe heat exchanger

期刊

APPLIED THERMAL ENGINEERING
卷 211, 期 -, 页码 -

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.applthermaleng.2022.118504

关键词

Double pipe heat exchanger; Non-dominated sorting genetic algorithm; Turbulent flow; Thermal performance index; multi-objective; optimization

资金

  1. Associaao Paranaense de Cultura (APC)
  2. National Council of Scientific and Tech-nologic Development of Brazil-CNPq [307958/2019-1-PQ, 307966/2019-4-PQ, 404659/2016-0-Univ]
  3. Fundaao Araucaria by PRONEX [042/2018]

向作者/读者索取更多资源

The thermal performance index (TPI), known as the efficiency parameter, evaluates the heat transfer highlight with the same pumping power requirement. Using multi-objective optimization techniques, the design of a double pipe heat exchanger with perforated baffles in the annulus side was improved, resulting in significantly enhanced heat transfer performance compared to a plain double pipe heat exchanger. The Nusselt number increased by approximately 8 times, and the friction factor increased by approximately 7-10 times.
The thermal performance index (TPI) known as the efficiency parameter evaluates the highlight of the heat transfer for the same pumping power requirement. The optimum design of a heat exchanger with minimum pressure drops and efficient heat transfer is a big challenging task from an energy-saving point of view. One way to optimize this efficiency parameter is by changing the geometric parameters of the heat exchanger. For this purpose, the multi-objective reinforcement learner non-dominated sorting genetic algorithm (NSGA-RL) is employed maximizing TPI and Nusselt number and minimizing Fanning friction factor to the optimal design of a double pipe heat exchanger, with perforated baffles in the annulus side. Its performance is compared with a nondominated sorting genetic algorithm - version II (NSGA-II), and a chaotic non-dominated sorting genetic algorithm (CNSGA). The calculations were carried out using the turbulent shear stress transport k-omega model. The multi-objective optimization techniques presented promising results in terms of the number of nondominated solutions, Euclidean distances to the origin point (reference point), and hypervolume indicators. However, in general, the results based on mean values indicate that the NSGA-RL outperforms the NSGA-II and CNSGA concerning the three performance indicators for the two double pipe heat exchanger evaluated cases. TPI increases 78% for case 1, and 108% for case 2 compared without baffles in a double pipe heat exchanger (DPHE). Numerical results revealed that DPHE employing internal perforated baffles improved heat transfer significantly with Nusselt number increased around 7.93-8.25 times and friction factor increased by 6.5-9.75 times compared with plain DPHE.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据