4.2 Article

Translation, cross-cultural adaptation and validation of the Computer Vision Syndrome Questionnaire into Persian (CVS-Q FA©)

期刊

INTERNATIONAL OPHTHALMOLOGY
卷 42, 期 11, 页码 3407-3420

出版社

SPRINGER
DOI: 10.1007/s10792-022-02340-3

关键词

Computer vision syndrome; Questionnaire; Cross-cultural adaptation; Validation; Occupational health

资金

  1. CRUE-CSIC agreement
  2. Springer Nature

向作者/读者索取更多资源

This study successfully translated, cross-culturally adapted, and validated the Computer Vision Syndrome Questionnaire (CVS-Q (c)) into Persian, providing a valid and reliable tool for assessing computer vision syndrome among the Iranian working population.
Purpose To translate, cross-culturally adapt and validate the Computer Vision Syndrome Questionnaire (CVS-Q (c)) into Persian. Methods This study was carried out in 2 phases: (1) the CVS-Q (c) was translated and cross-culturally adapted into Persian and (2) the validity and reliability of CVS-Q FA (c) were assessed in a cross-sectional validation study. An expert committee composed of 15 optometrists evaluated content validity (item-level (I-CVI) and scale-level (S-CVI) content validity index were calculated). A pretest was performed (n = 20 participants) to verify the comprehensibility of the questionnaire. A total of 102 computer users completed the final questionnaire. Criterion validity and diagnostic performance of the CVS-Q FA (c) were assessed by calculating sensitivity, specificity and receiver characteristic operator curve. Cronbach's alpha was calculated for the assessment of internal consistency and 46 participants refilled the questionnaire for the second time and the interclass correlation coefficient (ICC) and Cohen's kappa (kappa) were evaluated for test-retest reliability. Results The translation and cross-cultural adaptation process was performed successfully according to accepted scientific recommendations without any major difficulties. The I-CVI was above 0.80 for all items (symptoms) except item 15 (feeling that sight is worsening) and the S-CVI was 0.92. The CVS-Q FA (c) showed good sensitivity (81.1%) and acceptable specificity (69.2%). Also, it achieved good internal consistency (Cronbach's alpha = 0.80) and test-retest reliability (ICC = 0.81 and kappa = 0.65). Conclusion The CVS-Q FA (c) was successfully translated, cross-culturally adapted, and validated into Persian. This study provides a valid and reliable tool for the assessment of computer vision syndrome among the Iranian working population.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.2
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据