4.1 Article

Test-retest reliability of the FALL FIT system for assessing and training protective arm reactions in response to a forward fall

期刊

METHODSX
卷 9, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.mex.2022.101702

关键词

Upper extremity; Falls; Injury

资金

  1. University of Maryland Advanced Neuromotor Rehabilitation Research Training (UMANRRT) Program [P30AG028747, NIDRR 90AR50280]
  2. University of Maryland Claude D Pepper-OAIC NIH/NIA [NIDILRR 90AR5004]

向作者/读者索取更多资源

The use of hands and arms in fall prevention is essential. This study assessed the test-retest reliability of fall dynamics and protective arm response using the FALL FIT simulator, and found good to excellent reliability for most measures. FALL FIT can simulate various fall dynamics and is important for understanding protective arm reactions.
The use of the hands and arms is an important protective mechanism in avoiding fall-related injury. The aim of this study was to evaluate the test-retest reliability of fall dynamics and evokd protective arm response kinematics and kinetics in forward falls simulated using the FALL simulator For Injury prevention Training and assessment system (FALL FIT). Fall FIT allows experimental control of the fall height and acceleration of the body during a forward fall. Two falls were simulated starting from 4 initial lean angles in Experiment 1 and with 4 different fall accelerations in Experiment 2. Fourteen younger adults (25.1 +/- 3.5 years) and 13 older adults (71.3 +/- 3.7 years) participated in Experiment 1 and 13 younger adults (31.8 +/- 5.7 years) participated in Experiment 2. Intraclass correlation coefficients (ICC) were used to the evaluate absolute agreement of single measures at each condition and averages across conditions. Average measures of fall dynamics and evoked kinematics and kinetics exhibited excellent reliability (ICC(A,4) > 0.86). The reliability of single measures (ICC(A,1) > 0.59) was good to excellent, although 18% of single measures had a reliability (ICC(A,1)) between 0.00 and 0.57. The FALL FIT was shown to have good to excellent reliability for most measures. FALL FIT can produce a wide range of fall dynamics through modulation of initial lean angle and body acceleration. Additionally, the range of fall velocities and evoked kinematics and kinetics are consistent with previous fall research. The FALL FIT can be used to gain further insight into the control of protective arm reactions and may provide a therapeutic tool to assess and train protective arm reactions. (C) 2022 The Author(s). Published by Elsevier B.V.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.1
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据