4.3 Article

Measurements of Metastable N2(A3Σu+,v) Molecules in Nonequilibrium Supersonic Flows

期刊

JOURNAL OF THERMOPHYSICS AND HEAT TRANSFER
卷 36, 期 1, 页码 196-206

出版社

AMER INST AERONAUTICS ASTRONAUTICS
DOI: 10.2514/1.T6254

关键词

-

资金

  1. U.S. Air Force Office of Scientific Research project Energy Transfer Processes in Nonequilibrium Hypersonic Flows (technical monitor Ivett Leyva)

向作者/读者索取更多资源

Nonintrusive laser diagnostics were used to measure the populations of metastable nitrogen molecules in a nonequilibrium flow. Different diagnostic techniques were employed, including tunable diode laser absorption spectroscopy (TDLAS) and cavity ring down spectroscopy (CRDS), for characterizing the flow properties under different pressures.
Nonintrusive laser diagnostics are used for the measurements of metastable nitrogen molecules in the lowest excited electronic state, N-2(A(3)Sigma(+)(u)), in a nonequilibrium flow, blowdown supersonic wind tunnel. The tunnel is operated with nitrogen at plenum pressures of P-0=200-250 Torr, with the flow expanding through a two-dimensional contoured nozzle to the Mach number of M=3.6-4.6. The steady-state run time of the tunnel is approximately 10 s. The flow is excited by a repetitive nanosecond pulse discharge operated in the plenum or in the nozzle throat. Time-resolved absolute N-2(A(3)Sigma(+)(u),v=0) populations in the plenum are measured by single-pass, continuous wave tunable diode laser absorption spectroscopy (TDLAS). In the supersonic test section, absolute N-2(A(3)Sigma(+)(u),v=0-2) populations are measured by cavity ring down spectroscopy (CRDS), using a tunable pulsed laser system operated at 10 Hz. During each run, 50 single-shot ring down traces are acquired, demonstrating good shot-to-shot reproducibility. The results demonstrate that the cavity ring down time is not affected by the supersonic flow. N-2(A(3)Sigma(+)(u),v=0-2) populations and the flow temperature are inferred from the single-shot CRDS data. At the conditions when the flow is excited by the discharge in the nozzle throat, N-2(A(3)Sigma(+)(u),v=0) population in the supersonic test section is measured by both CRDS and TDLAS diagnostics. The two diagnostic techniques are complementary and can be used for characterization of nonequilibrium reacting flows over a wide range of pressures, including short-run-time high-enthalpy flow facilities.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据