4.6 Article

Sensorless Robust Flatness-Based Control With Nonlinear Observer for Non-Ideal Parallel DC-AC Inverters

期刊

IEEE ACCESS
卷 10, 期 -, 页码 53940-53953

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/ACCESS.2022.3175847

关键词

Inverters; Voltage control; Observers; Reliability; Loss measurement; Transient analysis; Trajectory; Flatness control; losses estimation; parallel inverters; sensorless control; nonlinear observer

向作者/读者索取更多资源

This paper proposes a one-loop sensorless controller based on the flatness technique for non-isolated power supply consisting of parallel inverters. The controller relies on a nonlinear online observer to estimate currents and voltages, and models system losses using equivalent voltage and current sources. The proposed controller achieves high dynamic performance, wide bandwidth, and low voltage THD.
Parallel operation of multiple AC/DC inverters is favorable in hybrid AC/DC microgrids to avert consecutive conversion stages and increase the system's efficacy. Yet, several emerging technical challenges impede the expansion of such layout such as the circulating currents, sensitiveness to the input voltage disturbances, load variations and complexity of the control structures caused by using several required measurements. This paper proposes a one-loop sensorless controller which is based on the flatness technique for a non-isolated power supply consisting of n-parallel inverters. The proposed control scheme primarily relies on employing a nonlinear online observer to estimate the line inductor currents and the dc link voltage via information from the input voltage, output voltage, and load conditions to avoid using excessive sensors. In this way, the system reliability is improved by reducing burdens of the communication delays and/or the failures, signal noise, thus the system is featured by simple control. Besides, the system entire losses are modeled by equivalent voltage sources and one current source which implicitly represent all types of the losses by using an online nonlinear estimator for the control purposes. The proposed controller not only has high dynamic performance, wide-bandwidth, low voltage THD but also robust to the abrupt variations in the load and the input voltage. To validate the applicability of the proposed control method and the observer, both simulations and experimental investigations are performed for two paralleled three-phase inverters setup. The obtained results assure the effectiveness of the proposed control method in regulating the output voltage of the parallel DC/AC inverters with fewer number of the sensors against the fluctuations of the input dc voltage and the load perturbations.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据