4.5 Article

The development of a rapid monitoring method for radiocesium in seawater in the Fukushima region

期刊

出版社

ROYAL SOC CHEMISTRY
DOI: 10.1039/d2ew00211f

关键词

-

资金

  1. Cultural Affairs and Missions Sector of the Egyptian Ministry of Higher Education

向作者/读者索取更多资源

This study presents a new monitoring method for the rapid assessment and quantification of low levels of radioactive cesium in Fukushima seawater. The method utilizes Prussian blue analogue nanoparticle slurries to achieve high recovery of cesium in the presence of competing ions.
Very recently, we reported the preparation of several types of Prussian blue analogue (PBA) nanoparticle (NP) slurries with varying compositions (KCuHCF-NPs, A(y)Cu[Fe(CN)(6)](1-x)center dot zH(2)O) and different NP sizes via systematically tuning the synthetic conditions using a Y-type micro-mixer at a high flow rate of 200 mL min(-1) for the recovery of cesium (Cs) from seawater in the presence of competing ions [Environ. Sci.: Water Res. Technol., 2019, 5, 1328-1338]. Here, we report a new monitoring method for the rapid assessment of low levels of radioactive Cs (137-Cs) and its effective concentration and quantification in Fukushima seawater, directly using KCuHCF-0.26 NPs (K1.02Cu[Fe(CN)(6)](0.74)center dot 2.63H(2)O) slurry ink. Laboratory test measurements of stable 133-Cs using KCuHCF-0.26 in simulated seawater showed Cs recovery exceeding 99.5% within 30 min. A pilot large-scale experiment conducted in conditioned seawater (100 L tank) with 137-Cs and 133-Cs (500 mu g L-1) using KCuHCF-0.26 slurry at Tokyo Power Technology Ltd (TPT), Japan, agreed with the laboratory results, exhibiting high Cs recovery efficiencies over a wide pH range of 5-9. A high adsorbent to solution ratio of 10 000 mL g(-1) was applied to selectively adsorb Cs in the presence of competing coexisting ions in seawater, meaning most 137-Cs in 1000 L of solution could be concentrated into only 0.1 kg of KCuHCF-NPs; thus, much lower levels of radiation in seawater could be recovered. The proposed method shortened the preconcentration and pre-treatment times of 137-Cs to ca. 30 min in a 100 L conditioned seawater tank and a germanium detector (Ge-detector) container packed with flocculated KCuHCF-0.26 flocs. This study examines the effectiveness of this method involving mixing KCuHCF-0.26 slurry ink, with strong Cs-adsorption abilities, with seawater containing 137-Cs, including the addition of 133-Cs as an elution suppression measure.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据