4.7 Article

Ultra-high-resolution imaging of the shoulder and pelvis using photon-counting-detector CT: a feasibility study in patients

期刊

EUROPEAN RADIOLOGY
卷 32, 期 10, 页码 7079-7086

出版社

SPRINGER
DOI: 10.1007/s00330-022-08925-x

关键词

X-ray computed tomography; Shoulder; Pelvis; Hip joint; Radiation dosage

资金

  1. Siemens Healthineers GmbH

向作者/读者索取更多资源

This study evaluated the ultra-high-resolution imaging of large joints using an investigational photon-counting detector CT. The results showed that the evaluated PCD-CT system provided improved visualization of osseous structures in the shoulders and pelvises at a lower radiation dose compared to the energy-integrating-detector CT. Trabecular delineation in shoulders and femoroacetabular joint visualization in the pelvis received the highest scores among the anatomic structures evaluated.
Objective To evaluate ultra-high-resolution (UHR) imaging of large joints using an investigational photon-counting detector (PCD) CT. Materials and methods Patients undergoing clinical shoulder or pelvis energy-integrating-detector (EID) CT exam were scanned using the UHR mode of the PCD-CT system. Axial EID-CT images (1-mm sections) and PCD-CT images (0.6-mm sections) were reconstructed using Br62/Br64 and Br76 kernels, respectively. Two musculoskeletal radiologists rated visualization of anatomic structures using a 5-point Likert scale. Wilcoxon rank-sum test was used for statistical analysis of reader scores, and paired t-test was used for comparing bone CT numbers and image noise from PCD-CT and EID-CT. Results Thirty-two patients (17 shoulders and 15 pelvis) were prospectively recruited for this feasibility study. Mean age for shoulder exams was 67.3 +/- 15.5 years (11 females) and 47.2 +/- 15.8 years (11 females) for pelvis exams. The mean volume CT dose index was lower on PCD-CT compared to that on EID-CT (shoulders: 18 mGy vs. 34 mGy, pelvis: 11.6 mGy vs. 16.7 mGy). PCD-CT was rated significantly better than EID-CT (p < 0.001) for anatomic-structure visualization. Trabecular delineation in shoulders (mean score = 4.24 +/- 0.73) and femoroacetabular joint visualization in the pelvis (mean score = 3.67 +/- 1.03) received the highest scores. PCD-CT demonstrated significant increase in bone CT number (p < 0.001) relative to EID-CT; no significant difference in image noise was found between PCD-CT and EID-CT. Conclusion The evaluated PCD-CT system provided improved visualization of osseous structures in the shoulders and pelvises at a 31-47% lower radiation dose compared to EID-CT.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据