4.7 Article

Improving the stability of frequency-dependent squeezing with bichromatic control of filter cavity length, alignment, and incident beam pointing

期刊

PHYSICAL REVIEW D
卷 105, 期 8, 页码 -

出版社

AMER PHYSICAL SOC
DOI: 10.1103/PhysRevD.105.082003

关键词

-

资金

  1. Advanced Technology Center of National Astronomical Observatory of Japan
  2. JSPS [15H02095, 18H01235, 21H04476, 18H01224, 18K18763]
  3. JSPS Core-to-Core Program
  4. EU Horizon 2020 Research and Innovation Programme under the Marie Sklodowska-Curie Grant [734303]
  5. Graduate University for Advanced Studies, SOKENDAI
  6. Japanese government Ministry of Education, Culture, Sports, Science and Technology scholarship
  7. Institute for Cosmic Ray Research Young Researcher's Fund
  8. JSPS Standard Postdoctoral Fellowship [20F20803, 20F20713]
  9. Deutsche Forschungsgemeinschaft (DFG, German Research Foundation) under Germany's Excellence Strategy [EXC 2123, 390837967]
  10. Japan Science and Technology Agency, Core Research for Evolutional Science and Technology [JPMJCR1873]
  11. Grants-in-Aid for Scientific Research [18K18763, 18H01235, 18H01224, 15H02095, 21H04476] Funding Source: KAKEN

向作者/读者索取更多资源

Frequency-dependent squeezing is a major upgrade for reducing quantum noise in gravitational wave detectors. In a squeezing experiment, it was found that the detuning fluctuations of the filter cavity can be mitigated by fixing the incident beam pointing and applying automatic alignment. The stable detuning variation of the filter cavity can reduce the fluctuation in the detection range of the gravitational wave detector from 11% to within 2%.
Frequency-dependent squeezing is the main upgrade for achieving broadband quantum noise reduction in upcoming observation runs of gravitational wave detectors. The proper frequency dependence of the squeezed quadrature is obtained by reflecting squeezed vacuum from a Fabry-Perot filter cavity detuned by half of its line width. However, since the squeezed vacuum contains no classical amplitude, copropagating auxiliary control beams are required to achieve the filter cavity???s length, alignment, and incident beam pointing stability. In our frequency-dependent squeezing experiment at the National Astronomical Observatory of Japan, we used a control beam at a harmonic of squeezed vacuum wavelength and found visible detuning variation related to the suspended mirrors angular drift. These variations can degrade interferometer quantum noise reduction. We investigated various mechanisms that can cause the filter cavity detuning variation. The detuning drift is found to be mitigated sufficiently by fixing the incident beam pointing and applying filter cavity automatic alignment. It was also found that there is an optimal position of the beam on the filter cavity mirror that helps to reduce the detuning fluctuations. Here, we report a stabilized filter cavity detuning variation of less than 10 Hz compared to the 113 Hz cavity line width. Compared to previously published results [Phys. Rev. Lett. 124, 171101 (2020), such detuning stability would be sufficient to make filter cavity detuning drift induced gravitational wave detector detection range fluctuation reduce from 11% to within 2%.